Gold Member Since 2013
Audited Supplier
Jiangsu YLD Water Processing Equipment Co., Ltd.

Water Purification, Water Filter, Water Filter System manufacturer / supplier in China, offering Hydro Cyclone Desander for Underground Water Treatment, Water Treatment Plant Hardness Removal Water Softening System, High Flow Bag Filter or The Water Filter Housing and so on.

(/ )

Supplier Homepage Product cyclone sand separator Hydro Cyclone Desander for Underground Water Treatment

Hydro Cyclone Desander for Underground Water Treatment

FOB Price: US $300-5,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $300-5,000/ Piece
Get Latest Price
Production Capacity: 5000 Sets/Year
Transport Package: Plywood Case Into Container
Payment Terms: L/C, T/T, D/P, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YLXC-40II
  • Usage: Environmental Protection, Chemical Industry, Water Treatment
  • Style: Vertical
  • Certification: CE
  • Material: Carbon Steel/Stainless Steel304//Ss316
  • Inlet and Outlet: Dn40mm
  • Turbidity of Raw Water: More Than300 Degrees
  • Input Water Pressure: More Than0.2-0.25MPa
  • Working Temperature: Normal
  • Specification: CE, SGS
  • HS Code: 8421219990
  • Type: Filter
  • Motive Force: Pressure
  • Performance: Efficient Filtration
  • Product Name: Hydro Cyclone Desander for Underground Water
  • Flow Rate: 25m3/H
  • Desanding Diameter: More Than0.1mm
  • Output Water Turbidity: Less Than10 Degrees
  • Water Head Loss: Less Than0.02MPa
  • Trademark: YLD
  • Origin: Jiangyin, Jiangsu, China
Product Description

Hydro cyclone desander for underground water treatment



Working Principle and Working Procedure
 
1,Process raw water - hydrocyclone sand separator -  micro filtration - water tanks - User
2,Working Principle
Hydrocyclone sand separator is based on the principle of centrifugal sedimentation and density difference, At a certain pressure, the flow into the device, have a strong rotary motion, due to the different densities of sand and water, under the effect of centrifugal force, centripetal buoyancy, fluid drag force, so that the low density of the water rises, discharged from the overflow port, high density of sand from the bottom, so as to achieve the purpose of grit removal. Under certain terms and conditions, the higher water pressure, the higher the grit removal rate, it can also be fixed in parallel.
 


Application
 
1,Domestic and industrial: river water, ground water, well water grit removal, coal washing water, industrial processing, solid-liquid separation;
 
2,Geothermal air conditioning water system to replace the current use of Ah type fan coil before decontamination, the complete elimination of the fan coil clogging dirt deposition and cooling water systems chiller condenser water decontamination, impurity control suspended solids and other issues;
 
3,Recycling water reuse: especially for steel, thermal, chemical, petroleum, mining, pharmaceutical, textile, electronics, food, paper and other industrial local quality miscellaneous drainage treatment and reuse;
 
4,Water, sewage treatment: reused water, sewage treatment plant, reduce fine filtration system into operation
FAQ:

1. What is capacity(m3/h or gpm)do you require?
2. What is the material do you want?--SS or carbon steel?
3. What is the operation do you want?---By manual or automatic?




Technical parameters:
   
Model of sand filter
  
Flow rate
(T/h)
Water inlet (mm) Water outlet (mm)  Ø diameter of cylinder
(mm)
  A1
(mm)
  B1
(mm)
 B2
(mm)
   H1
(mm)
   H2
(mm)
  H3
(mm)
YLXC–40I254025273220113220640140860
YLXC–50I405025273220108230680140910
YLXC–65I5065253252201242407801401030
YLXC–80I6080403252201182508301801095
YLXC–100I100100403772201342609202001205
YLXC–125I160125503773201223009802001310
YLXC–150I2001505047838015036010102001410
YLXC–200I2502005062044020043010652001550
YLXC–250I3002506572050022552011702001750
YLXC–300I5003006582058027459013752501990



Installation Precautions
 
1. Hydrocyclone sand separator should be installed in the main pipe of water supply network and fixed on the base, we need to add a bypass between the inlet and outlet.
 
2. In order to ensure smooth water flow in front of the device should be installed intake and intake period equal diameter of straight pipe length equivalent to 10 to 15 times the diameter of the intake.
 
3. The equipment should be installed around the reserve has enough space for maintenance.
 
4.During normal operation, the need to open the inlet and outlet valves, close the drain valve and bypass valve.
 
5.depending on how much sand content of regular source of water decontamination platoon sand, open the drain valve at the sewage, water can flow out until the sewage process does not affect the normal use of water.
 
6.After sewage, close the drain valve.
 
7. If lack of sand discharge pressure, close the valve at the outlet.
 