• High Efficient Sterilization UV Disinfection System
  • High Efficient Sterilization UV Disinfection System
  • High Efficient Sterilization UV Disinfection System

High Efficient Sterilization UV Disinfection System

Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Flow Rate: 200m3/H
Inlet and Outlet: Dn200mm
Lifespan of UV Lamp: 9000-12000 Hours
Interface Type: Flange or Thread
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLC-1500
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Swimming Pool
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
842121999
Production Capacity
5000 Sets/Year

Product Description


High efficient sterilization UV disinfection system



 

UV disinfection system Features:
 
1.Adopting high efficiency UV-C (LL or LH) lamp
About UV sterilizer adopts world leading low pressure and high strength UV tube, whose operation life is above 9000 hours.
2. Adopting high light transmittance, high purity quartz drive pipe, ensure UV rays transmittance rate above 90%.
3. Adopting world advanced constant high strength UV special ballast, ensure the whole system normally operate in a complex condition.

High Efficient Sterilization UV Disinfection System
High Efficient Sterilization UV Disinfection System

High Efficient Sterilization UV Disinfection System



 UV Disinfection Systems Application
 
1. Food processing and industrial water disinfection
 
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
 
3. Municipal water
 
4. Biochemical pharmaceutical, cosmetics production water disinfection
 
5. Aquatic products processing water disinfection
 
6. Swimming pool water disinfection
 
7. Seawater, freshwater aquaculture breeding water disinfection
 
8. Ultra-pure water for electronic industry, and so on





 
What does a UV sterilizer do?
A UV sterilizer is used to control infections by stopping the spread of microorganisms from one fish/coral/invertebrate to another through the water. It is also used in pond applications to control free-floating algae. When operated correctly, free-floating microorganisms will be killed by the UV light. Note that the organisms must be in the water that flows to the UV sterilizer. The UV light has no residual effect and will not kill organisms attached to fish (e.g., adult stage of ich) or rocks (e.g., algae).






Technical parameters:
model Processing capacity (Ton/Hour) power (W)  inlet and outlet
(inch)
working pressure (Kg/cm 2 ) malfunction alert for UV lamp reactor dimension (cm) L×W×H dimension of panel(cm) anchor bolt  (cm) overall weight (Kg)
YLCn-005 0.3 16 1/2" 6 matched 30×6×11     5
YLCn-008 1 25 1/2" 6 matched 47×6.3×11     10
YLCn-050 2 40 1" 6 matched 100×9×20 Φ8.9×25
(diameter×length)
69×4×Φ1 25
YLCn-150 6 80 1+1/4" 6 matched 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2" 6 matched 100×15.9×30 Φ8.9×45
(diameter×length)
69×7×Φ1 35
YLCn-300 12 160 2" 6 matched 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1" 6 matched 100×8.9×30 25×30×12
(L×H×w)
60×4×Φ1 45
YLC-150 6 80 DN32/1 1/4 " 6 matched 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/1 1/2 " 6 matched 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2" 6 matched 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/2 1/2" 6 matched 100×15.9×40 50×78×25
(L×H×W)
60×7×Φ1 120
YLC-500 20 240 DN65/2 1/2" 6 matched 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3" 6 matched 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5" 6 matched 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6" 6 matched 170×27.3×57 60×128×30
(W×H×T)
 
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6" 6 matched 173×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8" 6 matched 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8" 6 matched 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10" 6 matched 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10" 6 matched 176×52.9×95 60×150×40
(W×H×T)
120×28×Φ2.2 475
YLC-15K 600 3080 DN300/12" 6 matched 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14" 6 matched confirmed  confirmed confirmed confirmed
YLC-25K 1000 4760 DN350/14" 6 matched confirmed confirmed confirmed




FAQ:
Q. How do ultraviolet ("UV") sterilizers work? 
A. UV sterilizers work by exposing water to powerful germicidal ultraviolet light. DNA and protein links in bacteria are destroyed by exposure to this light. 
 
Q. Does the water become radioactive by this radiation? 
A. No. No radiation residual or any chemical residual is left in the water as a result of the UV rays.
 
Q. Do these systems come in different sizes? 
A. Yes. The size of the systems is directly proportional to the flow rate of the water in gallons per minute. The higher the flow rate, the larger the system and lamp. 
 
Q. Does the water have to sit in the UV sterilizer to be disinfected? 
A. No. If the system is sized correctly, the water is disinfected as it flows through. 
 
Q. What if the water flows faster than is allowed through the system? 
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded. 
 
Q. How long does the lamp last? 
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water. 
 
Q. Are these systems bigger energy users? 
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
 
Q. My water is sometimes cloudy. Is that a problem? 
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated. 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now