• Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
  • Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
  • Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
  • Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
  • Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
  • Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant

Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant

Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Inlet and Outlet: Dn100mm/4 Inch
Lifespan of UV Lamp: 9000-12000 Hours
Interface Type: Flange
Flow Rate: 40m3/H
Samples:
US$ 800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLC-1000
Chamber Size
930*159*370mm
Working Pressure
(0.6 MPa
Raw Water
Drinking Water/Waste Water/Underground Water
Brand of Ballast
Domestic Brand
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

Ultraviolet Water Purification UV water treatment Plant
 

UV water treatment offers many advantages over other forms of water treatment for microbiological contaminants. Most importantly, it does not introduce any chemicals to the water, it produces no bi-products, and it does not alter the taste, pH, or other properties of the water. Accordingly, in addition to producing safe drinking water, it is not harmful to your plumbing and septic system. Furthermore, it is easy and cost-effective to install and maintain without any special training.Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant
How UV Works

Ultraviolet purification uses a UV light source (lamp) which is enclosed in a protective transparent sleeve (usually quartz). The lamp is mounted such that water passing through a flow chamber is exposed to the UV-C light rays. When harmful microbes are exposed to the UV rays, their nucleic acid absorbs the UV energy, which then scrambles the DNA structure of the organism. The cell is rendered sterile and can no longer reproduce. The cell is now considered dead and is no longer a threat.






What Contaminants Do UV Sterilizers Remove? 
 
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%. 


Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant

 
CONVENTIONAL METHODS OF WATER TREATING
  CHLORINE OZONE ULTRA VIOLET
Capital cost Lowest High Low
Ease of installation Good Poor Excellent
Ease of Maintenance Good Poor Excellent
Cost of Maintenance Medium High Lowest
Operating Cost Low High Low
Frequency Of Maintenance Frequent Continuous V. Infrequent
Control System Poor Good Excellent
Virucidal Effect Good Poor Good
Toxic Chemical Yes Yes No
Residual Effect Problem with Yes Yes No
Hazards High Yes Low to none
Contact Time 30 - 60 minutes High 1 - 5seconds
Disinfection Performance Leaves some pathogens Kills all microbes Kills all microbes
Effect on Water Organochlorine compounds, Taste & pH changes Unknown None
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed.




Ultraviolet Water Purification UV Water Sterilizer Water Treatment Plant


Technical parameters:

model

capacity

Power

inlet-outlet

reactor

panel

Anchor

G weight

 

m³/hour

watt

mm

L×W×H

cm

screw

Kg

YLCn-005

0.3

16

1/2″

30×6×11

without

without

5

YLCn-008

1

25

1/2″

47×6.3×11

without

without

10

YLCn-050

2

40

1″

100×9×20

Φ8.9×25
(d×L)

69×4×Φ1

25

YLCn-150

6

80

1+1/4″

100×11×23

 

69×4×Φ1

30

YLCn-200

8

120

1+1/2″

100×15.9×30

Φ8.9×45
(d×L)

69×7×Φ1

35

YLCn-300

12

160

2″

100×15.9×32

 

69×7×Φ1

40

YLC-050

2

40

DN25/1″

100×8.9×30

25×30×12
(W×H×D)

60×4×Φ1

45

YLC-150

6

80

DN32/11/4″

100×10.8×30

 

60×4×Φ1

50

YLC-200

8

120

DN40/11/2″

100×15.9×40

 

60×7×Φ1

60

YLC-300

12

160

DN50/2″

100×15.9×40

 

60×7×Φ1

70

YLC-360

15

200

DN65/21/2″

100×15.9×40

 

60×7×Φ1

120

YLC-500

20

240

DN65/21/2″

100×21.9×50

 

60×11×Φ1.2

130

YLC-600

25

280

DN80/3″

100×21.9×50

 

60×11×Φ1.2

140

YLC-700

30

320

DN100/4″

100×21.9×50

 

60×11×Φ1.2

150

YLC-1000

40

360

DN100/4″

100×21.9×50

 

60×11×Φ1.2

160

YLC-1200

50

400

DN125/5″

100×21.9×50

 

60×11×Φ1.2

180

YLC-1500

60

420

DN150/6″

170×27.3×57

 

120×16×Φ1.4

210

YLC-2000

80

560

DN150/6″

170×27.3×57

 

120×16×Φ1.4

220

YLC-2500

100

700

DN150/6″

170×27.3×57

60×128×30
(W×H×D)

120×16×Φ1.4

275

YLC-3000

125

840

DN150/6″

170×27.3×57

 

120×16×Φ1.4

300

YLC-4000

150

1120

DN200/8″

173×32.5×65

 

120×20×Φ1.6

325

YLC-5000

200

1400

DN200/8″

173×37.7×72

 

120×22×Φ1.6

350

YLC-7000

300

2100

DN250/10″

175×42.6×80

 

120×24×Φ2.0

400

YLC-10K

400

2520

DN250/10″

176×52.9×95

60×150×40
(W×H×D)

120×22×Φ2.2

475

YLC-15K

600

3080

DN300/12″

176×78×110

 

120×32×Φ2.4

600

YLC-20K

800

3920

DN350/14″

Designated

Designated

Designated

Designated

YLC-25K

1000

4760

DN350/14″

Designated

Designated

Designated

Designated
 






 
Typical Maintenance Requirements

UV lamps (bulbs) require annual replacement to ensure optimal performance. UV lamp performance, just like any other light source, will slowly diminish over time. Beyond one year, there is no assurance that the UV light emitted from the bulb will provide sufficient disinfection. Remember, UV light cannot be seen. The bulb may still produce light, but not necessarily UV rays. The quartz sleeve does not need replacement unless it gets broken, however, it should be cleaned several times per year (outside only).







Frequently Asked Questions About Ultraviolet (UV) Purification

1. What is UV? 
Ultraviolet (UV) light is at the invisible, violet end of the light spectrum. Even though we can't see UV light, we are exposed to UV rays from all light sources, including the sun.
2. How does ultraviolet light purify water? 
UV-C rays penetrate the cells of harmful bacteria and viruses in our drinking water, destroying their ability to reproduce. Without this ability, these organisms die and no longer pose a health threat. It is a simple but very effective process, with the system destroying 99.99% of harmful microorganisms.
3. Why not use chlorine instead? 
Chlorine changes the taste and odor of water. Chlorinating also produces harmful by-products called Trihalomethanes (THMs) which are linked to incidence of cancer.
4. Does a UV system use a lot of energy? 
No, the UV unit will use about the same amount of energy as a 60 watt light bulb. It is a cost effective, natural way to increase water quality.
5. Why do UV purifiers require sediment pre-filtration? 
UV systems require pre-filtration to maintain effectiveness as sediment and other contaminants in the water can create a "shadow" which prevents the UV rays from reaching and disinfecting the harmful microorganisms.
6. How often does the UV light bulb (lamp) need to be replaced? 
It is essential that you change your UV lamp annually. The ability of the lamp to emit UV light decreases over one year in operation. Remember - UV light is invisible! Even though the lamp is still glowing after one year, there might not be enough UV light reaching your water to be effective.
7. How often do your need to replace the sleeve? 
The sleeve doesn't need to be replaced unless it is broken, but it will need to be cleaned several times a year in order to keep the bulb effective in delivering high water quality.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now