Water Sand Seperation Hydro Cyclone Desander For River Water
Product Description
How does a cyclone separator work?
The particles of dust and dirt that enter the cyclone are heavier than the air that surrounds them. Because of this, more force is needed to keep the debris continuously moving in a circular motion, although the force of the air that is inside the chamber isn't that strong. As the air continues to spin, the heavier particles of dirt and dust begin to separate from the other debris and move toward the walls of the chamber, sliding to the bottom of the container's dust bin.
The clean air that is located at the bottom of the cyclone begins to change directions as it moves up the center of the container's cylinder. From there the clean air travels to an exhaust tube or outlet that is usually attached to a filter that catches fine particles of debris that remain in the air. Cyclone separators are also used to remove pollutants from the air, gas and water.
There are a variety of cyclone separators that are used to perform these jobs that generally function in the same way by separating larger particles of debris from the air or other substances. These include cyclone grease separators, horizontal dust collectors, multiple cyclone separators, secondary airflow separators and hydrocyclonic separators.
Product characteristics:
1.No energy consumption, good sand removing effect, especially suitable for sand content higher system using.
2.Low cost, convenient installation and operation, safe and reliable operation, small size, processing a large quantity of water, small occupied area.
MAINTENANCE
Apply a layer of grease to handle threads once a year.
Immediately repair any damage to the tank's protective coating.
Product Parameters
FAQ:
1. What is capacity(m3/h or gpm)do you require?
2. What is the material do you want?--SS or carbon steel?
3. What is the operation do you want?---By manual or automatic?
Technical parameters:
Model |
Flow rate (T/h) |
Inlet & outlet dia. (mm) |
Darin dia. (mm) |
D (mm) |
H (mm) |
Weight (kg) |
YLXC-25II |
18 |
25 |
25 |
273 |
1100 |
40 |
YLXC-40II |
25 |
40 |
25 |
273 |
150 |
50 |
YLXC-50II |
40 |
50 |
25 |
273 |
1300 |
60 |
YLXC-80II |
60 |
80 |
40 |
325 |
1350 |
120 |
YLXC-100II |
100 |
100 |
40 |
377 |
1400 |
130 |
YLXC-125II |
160 |
125 |
50 |
377 |
1500 |
180 |
YLXC-150II |
200 |
150 |
50 |
426 |
1600 |
240 |
YLXC-200II |
250 |
200 |
65 |
530 |
1700 |
350 |
YLXC-250II |
300 |
250 |
65 |
630 |
1800 |
400 |
YLXC-300II |
500 |
300 |
65 |
720 |
1900 |
480 |
Installation Instructions
1. Hydrocyclone sand separator should be installed in the main pipe of water supply network and fixed on the base, we need to add a bypass between the inlet and outlet.
2. In order to ensure smooth water flow in front of the device should be installed intake and intake period equal diameter of straight pipe length equivalent to 10 to 15 times the diameter of the intake.
3. The equipment should be installed around the reserve has enough space for maintenance.
4.During normal operation, the need to open the inlet and outlet valves, close the drain valve and bypass valve.
5.depending on how much sand content of regular source of water decontamination platoon sand, open the drain valve at the sewage, water can flow out until the sewage process does not affect the normal use of water.
6.After sewage, close the drain valve.
7. If lack of sand discharge pressure, close the valve at the outlet.
Packaging & Shipping
After Sales Service
We provide 24 hours online customer service.
Any inquiry about water treatment system, please feel free to contact me for further details!
Guarantee period:1 year
Certifications