Manual Control Backwash Activated Carbon Filter For Wastewater
Activated carbon (AC) is a natural material derived from bituminous coal, lignite, wood, coconut shell etc., activated by steam and other means, and each one have different adsorption properties (e.g. bituminous carbon for high chlorine reduction capacity). Some manufacturers use various blends of carbon to achieve specific water quality and contaminants reduction (e.g. coconut shell carbon for "sweet taste").
Our granular activated carbons and filtration systems remove organic and inorganic contaminants from groundwater, surface and process water, wastewater and air/vapor streams. With permanent or removable adsorber equipment options and carbons backed by an industry-leading quality assurance program, Konche gives customers the right configuration for their application and flowrate, while also assuring optimal carbon utilization.
1. work pressure:0.25Mpa
2. filter speed:10-15m3
3. back flushing time:4-10min
4. regenerate time:15-30min
5. inlet water turbidity:<=10mg/L
6. outlet water turbidity:<=3mg/L
7. work temperature:4-50
8. wipe off rate:90-96%
9. back flushing intension:12-18L/S.m2
10. resistance loss:<=0.1Mpa
11. design prssure:0.6Mpa
Filter:
When the system is in a filtered State, the water flow through the water distributor which was unallowed,comply with shell,the water flow through the filter layer at the horizontal - flow state,as the water flowthe filter material layer, impurities are trapped within the filter layer,The filtered water is collected and evenly through water outflow,flowing parallel,at the high speed ,the filter could work well,and it can reach better effect too.
Backwash
With the continued accumulation of impurities in filter material layers, increasing loss of head,as the loss of head reaches a certain set limit, system will automatically be converted to the anti - washing, cleaning accumulation of impurities,
Backwashing happens at the differential pressure reaches 0. 05-0. 07Mpa,each time.and while the backwashing is over the differential pressure will back to 0.02-0.03Mpa.
TPYE |
TANK SIZE
(mm) |
TOTAL HIGH
(mm) |
FLOW RATE
(m3/hr) |
INLET AND OUTLET
(mm) |
YLD-MF-500 |
500*1500 |
2350 |
2 |
DN32 |
YLD-MF- 600 |
600*1500 |
2380 |
2-3 |
DN32 |
YLD-MF- 700 |
700*1500 |
2400 |
4 |
DN40 |
YLD-MF- 800 |
800*1500 |
2400 |
5 |
DN40 |
YLD-MF- 900 |
900*1500 |
2500 |
6 |
DN50 |
YLD-MF- 1000 |
1000*1500 |
2600 |
8 |
DN50 |
YLD-MF- 1200 |
1200*1500 |
2700 |
11 |
DN65 |
YLD-MF- 1400 |
1400*1500 |
2800 |
15 |
DN65 |
YLD-MF- 1500 |
1500*1500 |
2850 |
18 |
DN65 |
YLD-MF- 1600 |
1600*1500 |
2900 |
20 |
DN80 |
YLD-MF- 1800 |
1800*1500
1800*1800 |
3000 |
25 |
DN80 |
YLD-MF- 2000 |
2000*1500 |
3100 |
30 |
DN100 |
YLD-MF- 2200 |
2200*1500 |
3180 |
38 |
DN100 |
YLD-MF- 2400 |
2400*1500 |
3330 |
45 |
DN100 |
YLD-MF- 2500 |
2500*1500 |
3380 |
50 |
DN100 |
YLD-MF- 2600 |
2600*1500 |
3430 |
55 |
DN125 |
YLD-MF- 2800 |
2800*1500 |
3530 |
60 |
DN125 |
YLD-MF- 3000 |
3000*1500 |
3630 |
70-80 |
DN125 |
YLD-MF- 3200 |
3200*1500 |
3730 |
80~100 |
DN150 |
FAQ:
01. What is your raw water?
02. What is the flow rate per hour?
03. What is the power supply in your country?
04. What is the working pressure?
05. Do you need automatic or manual control system for this carbon filter?