Sewage ultraviolet disinfection module Open channel type UV water sterilizer
Channel-type disinfector
The open sewer disinfection technical system adopts the advanced IN-C disinfection technology through the special process design. high-efficiency, high-intensity and long service life UV-C lamp tubes, superior for the ballasts of reliable performance and electric-control system. It adopts the UV-C wave (T254nm) in high-efficiency and broad-spectrum killing of the bacteria and viruses so as to achieve the goal of water purification and disinfection.
As the first-class high-efficiency UV-C lamp tubes and superior-performance electric control system, the UV disinfection system enjoys power consumption far lower than that of the traditional UV disinfection system. In terms of the system design, designers of our Company have paid full attention to the attenuation of light intensity of UV lamp tubes within the service life and decrease of sterilization rate due to reduction of light intensity caused by sedimentation on the surface of the quartz tubes. Therefore, a large margin has been set when designing the disinfection system. Even when the light intensity of the lamp tubes drops to 60% of the rated value, the whole system can maintain normal operation. It has so far been broadly accepted in more and more fields for its unique and advantageous performances (particularly in disinfection of large water bodies and recycled reclaimed water).
Product advantages:
1.High efficiency: instant kill all bacteria, viruses. Disinfection of water within the rated range, depending on the water quality, the sterilization rate of 99.999%.
2. High quality: the use of high-quality UV C lamp, lamp life up to 9000 hours.
3.Stability: the device can be 24 hours of continuous operation.
4.High reliability: UV lamp which uses ultraviolet C (254nm) output utilization up to 95%.
5.Practical: used in drinking water, food processing, water disinfection, without changing shape of the water and food, colors, flavors, does not produce any disinfection byproducts. Low running costs, operation and maintenance easier, the devices are small, no noise.
UV disinfection module design advantages:
Material module is 316L stainless steel, the whole system lamp sockets, power sockets and wires laying mounted above the sewage channel, individual settings for each module, and without securely suspended above the sewage in the open channel, so replace the lamp or quartz tube, each module can be individually lifted without affecting the other modules.
Modules for advection design, effectively reduce head loss UV module, but also has good sealing performance, to protect the safety of use. In the same number of lamps, advection provides maximum UV intensity and dose.
Water quality factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution
Disinfection system factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Hydrodynamic design of the sterilizer (Maximize the use of UV performance to increase the disinfector efficiency and reduce the water pressure loss
2. Lamp tube performance (including the system aging)
3. Arrangement of lamp tubes
4. Scale coefficient of lamp tubes
5. Performance of ballast
Automatic cleaning device |
1. Mechanical self_cleaning device driven by compressed air;
2. The cleaning device and the uv light intensity detector are in linked operation;
3. Having (the optional) manual or automatic working statuses;
4. The low_abrasion and locking_free advantages have laid solid foundation for the UV system to realize the high_efficiency sterilization. |
Advanced control system |
1. The automatic control center has the remote_control and site_control functions, equipped with the world_class parts and components of superior quality and reliable operating performance.
2. The site control is conducted by the man_machine interface, which consists of the operation recording, fault alarming and maintenance warning functions, easy and simple to operate.
3. The UV intensity output and signal PLC link_control can be monitored online so as to guarantee the UV dosage which can achieve the designed disinfection effect. |
Applicable Range |
It is applicable to disinfection of water for the large, medium and small sewage treatment plants, landscape water, aquaculture water, reclaimed water recycling and hospitals. |
UV Frequently Asked Questions
What is a UV Water Treatment System?
A UV Water Treatment systems uses a method known as Ultraviolet germicidal irradiation (UVGI). This method uses ultraviolet (UV) light at sufficiently short wavelength to kill microorganisms. It is predominantly used in situations where there is a private water supply treatment requirement.
UV effective against protozoa such as Cryptosporidium & Giardia lamblia?
Yes, it is proven that UV is the best available technology to treat these protozoan cysts. In addition,the dose levels required to inactivate these cysts are actually quite low: less than 10mJ/cm2 for 99.9% reduction of Cryptosporidium parvum and Giardia lamblia.
Why disinfect a water supply?
Disinfection is recommended for all water supplies that are not protected by a municipal water source. Unfortunately, due to the uncertainties that exist with some current water supplies, it is not necessarily safe to rely on the fact that water supplies "may be safe".