316SS Chamber UV Water Sterilizer for TOC reduction
There are several advantages of using UV water filtration system rather than a chemical
disinfection solution (such as chlorination):
1.No known toxic or significant nontoxic byproducts
2.No danger of overdosing
3.Does not require storage of hazardous material
4.Adds no smell to the final water product
5.Requires very little contact time
Ultraviolet Water Sterilizer Equipment is an efficient and rapid method of water disinfection without the use of heat or dangerous chemicals. Impact no taste or odor to water, it utilize germicidal ultraviolet light to quickly and reliably disable bacteria, viruses and other microorganisms present in water.
Inexpensive, Simple Operation, low operating cost and maximum efficiency make UV water sterilizer equipment suitable for a wide range of uses
Product application
* Water disinfection of food processing industry, including juices, milk, drinks, beer, practical oil, and all kinds of canned food, beverage products, such as water disinfection.
* Ultra-pure water for electronic industry.
* Hospitals, various laboratory water disinfection, and high levels of pathogenic body water disinfection.
* Water disinfection applications, including residents of households building, residential, office building, hotels, restaurants, water factory.
* Fish processing purification and disinfection, purification and disinfection of shellfish, fish cleaning and disinfection process.
* Military camp, field water supply system.
* Urban wastewater disinfection, the maximum capacity of up to 1 million tons or more per day.
* Swimming pool, other recreational water disinfection water.
* Cooling water disinfection, including thermal power, nuclear power plant cooling water, industrial cooling water, cooling water, central air conditioning system.
* Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
* Sea water, fresh water breeding, aquaculture (fish, eel, shrimp, abalone, shellfish, etc. ) water, the total treated water up to 200 thousand tons per day or more.
* Agricultural water disinfection, including greenhouse water use and irrigation.
Principle of Operation
UV sterilizers work on the principle that special fluorescent UV lamps can effectively irradiate (kill) microorganisms in aquarium water when they are exposed to this light. UV light, at a peak wavelength of approximately 254 nanometers, alters the genetic material in the organism's nucleus and shortens its normal life cycle. Theoretically, UV sterilizers can kill viruses, bacteria, algae, and protozoa with no residual effects. However, the organisms must be free-floating and travel through the UV sterilizer unit for the sterilizer to work. It has no effect on organisms attached to fish or rocks because they do not flow through the unit and cannot be exposed to the UV light.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
model |
Processing capacity (Ton/Hour) |
power (W) |
inlet and outlet
(inch) |
working pressure (Kg/cm 2 ) |
malfunction alert for UV lamp |
reactor dimension (cm) L×W×H |
dimension of panel(cm) |
anchor bolt (cm) |
overall weight (Kg) |
YLCn-005 |
0.3 |
16 |
1/2" |
6 |
matched |
30×6×11 |
|
|
5 |
YLCn-008 |
1 |
25 |
1/2" |
6 |
matched |
47×6.3×11 |
|
|
10 |
YLCn-050 |
2 |
40 |
1" |
6 |
matched |
100×9×20 |
Φ8.9×25
(diameter×length) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4" |
6 |
matched |
100×11×23 |
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2" |
6 |
matched |
100×15.9×30 |
Φ8.9×45
(diameter×length) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2" |
6 |
matched |
100×15.9×32 |
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1" |
6 |
matched |
100×8.9×30 |
25×30×12
(L×H×w) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/1 1/4 " |
6 |
matched |
100×10.8×30 |
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/1 1/2 " |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2" |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/2 1/2" |
6 |
matched |
100×15.9×40 |
50×78×25
(L×H×W) |
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/2 1/2" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6" |
6 |
matched |
170×27.3×57 |
60×128×30
(W×H×T)
|
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6" |
6 |
matched |
173×27.3×57 |
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8" |
6 |
matched |
173×32.5×65 |
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8" |
6 |
matched |
173×37.7×72 |
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10" |
6 |
matched |
175×42.6×80 |
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10" |
6 |
matched |
176×52.9×95 |
60×150×40
(W×H×T) |
120×28×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12" |
6 |
matched |
176×78×110 |
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
confirmed |
YLC-25K |
1000 |
4760 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
FAQ
Is UV 100% effective?
UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses.
Does UV remove E. coli?
Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system.
How much does it cost to operate? UV systems are extremely economical to operate.
A typical household UV system operates on the same power requirements as a 40 watt light bulb!
Will UV change the taste or smell of my water?
UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection.
Why do I need Disinfection?
Disinfection is required on all water supplies that are not protected by a municipal water source. Due to the uncertainties that exist within some water systems, we can no longer rely on the fact that our water supplies "may be safe." By providing your own disinfection, you are taking the responsibility of ensuring the safety of the water supply for you and your family.
Do I need to Disinfect My Municipal Water Supply?
Our municipalities work very hard to provide safe disinfected water supplies to their customers. However, you may wish to give yourself that added "peace of mind" and install a UV sterilizer to protect against the possibility of drinking contaminated water.
What are the annual maintenance requirements?
UV systems contain no mechanical parts that wear out or require maintenance. UV lamps have a useful life of approximately 8,000 hours and require replacement annually. Proper maintenance of any pretreatment system is also required.