Ultra Violet Sterilizer UV Water Disinfection Filter
Detailed Product Description
UV light
UV light can efficiently reduce microbiological growth in water. UV radiation with a wavelength of 254 nanometers kills bacteria, viruses, algae, and fungi by destroying the DNA of the microorganisms. Disinfection by UV light is applicable to almost all water types.
What Contaminants Do UV Sterilizers Remove?
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%.
Advantages
There are several advantages of using UV water filtration system rather than a chemical
disinfection solution (such as chlorination):
1.No known toxic or significant nontoxic byproducts
2.No danger of overdosing
3.Does not require storage of hazardous material
4.Adds no smell to the final water product
5.Requires very little contact time
Application
Water Treatment |
Bottling |
Mineral Water |
Pharmaceuticals |
Dairies |
Distilleries |
Breweries |
Hospitals |
Food Industries |
Hotels |
Chemical Industries |
Cosmetics |
Gelatin |
Aqua Cultures |
Electronic Industries |
Algae and slime control |
Paint Industries |
Hatcheries |
Pretreatment before RO |
Swimming Pool etc. |
Cooling Towers |
DM Water Plant |
Sugar Syrups |
Poultry Farm
|
UV specification
Ultraviolet light treatment is a widely recognized and proven method of disinfection of water and has several advantage over other disinfection methods such as chlorination, ozonation, etc. UV light does not add anything to the water, such as, undesirable color, odor, taste, or flavor, nor does it generate harmful byproducts. It adds only energy in the UV radiation. Also, UV disinfection requires only a fraction of the contact times required by other disinfection methods. It is fast, efficient, effective, economical and environmentally-friendly.
Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
model |
Processing capacity (Ton/Hour) |
power (W) |
inlet and outlet
(inch) |
working pressure (Kg/cm 2 ) |
malfunction alert for UV lamp |
reactor dimension (cm) L×W×H |
dimension of panel(cm) |
anchor bolt (cm) |
overall weight (Kg) |
YLCn-005 |
0.3 |
16 |
1/2" |
6 |
matched |
30×6×11 |
|
|
5 |
YLCn-008 |
1 |
25 |
1/2" |
6 |
matched |
47×6.3×11 |
|
|
10 |
YLCn-050 |
2 |
40 |
1" |
6 |
matched |
100×9×20 |
Φ8.9×25
(diameter×length) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4" |
6 |
matched |
100×11×23 |
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2" |
6 |
matched |
100×15.9×30 |
Φ8.9×45
(diameter×length) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2" |
6 |
matched |
100×15.9×32 |
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1" |
6 |
matched |
100×8.9×30 |
25×30×12
(L×H×w) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/1 1/4 " |
6 |
matched |
100×10.8×30 |
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/1 1/2 " |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2" |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/2 1/2" |
6 |
matched |
100×15.9×40 |
50×78×25
(L×H×W) |
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/2 1/2" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6" |
6 |
matched |
170×27.3×57 |
60×128×30
(W×H×T)
|
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6" |
6 |
matched |
173×27.3×57 |
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8" |
6 |
matched |
173×32.5×65 |
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8" |
6 |
matched |
173×37.7×72 |
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10" |
6 |
matched |
175×42.6×80 |
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10" |
6 |
matched |
176×52.9×95 |
60×150×40
(W×H×T) |
120×28×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12" |
6 |
matched |
176×78×110 |
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
confirmed |
YLC-25K |
1000 |
4760 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |