• 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
  • 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
  • 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
  • 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
  • 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
  • 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System

25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System

Certification: ISO9001, CE
Application: Industry
Voltage: 220V
Disinfection Method: Ultraviolet
Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Customization:

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YLC-600
Inlet and Outlet
Dn200mm/8 Inch
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange
Flow Rate
150m3/H
Chamber Size
1630*273*530mm
Working Pressure
(0.6 MPa
Raw Water
Drinking Water/Waste Water/Underground Water
Brand of Ballast
Domestic Brand
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description


25m3/h 280W Mual Cleaning UV Water Purification System

Water Quality
 
Successful disinfection depends upon exposing water to a sufficient intensity of UV light for a sufficient amount of time. Water failing to meet certain general water quality guidelines may reduce the effectiveness of a system.For a UV system to work effectively the water must be pre-filtered to exclude any particles larger than 5 microns (nominal) in size. This pre-filtration assures that particles large enough to block the UV light do not pass through the system. If they do the particles can act as a shield between the microorganism and the UV light - protecting the microorganism and allowing it to pass into the product water unharmed and alive.If your water is not cloudy or smelly, you do not have rust stains in your toilet, and have softened water, your water, water quality should not be an issue for your UV system.




Micro organisms including bacteria, viruses and cysts are all around us naturally. Many are harmless but exposure to "bad" ones can cause severe illness particularly in the elderly and very young. There is a wide variety of water treatment products available to improve taste, clarity, scale etc but none of these are designed to combat bacteria. Ultra violet water treatment is one of the safest ways to disinfect water as the UV rays are a natural component of sunlight. No chemicals are added so there is no danger from overdosing or creating a bad taste



Usages and Advantages
· Effective: Virtually all microorganisms are susceptible to UV disinfection
· Automatic: Continuous or intermittent disinfection without special attention
· Fast: Water is ready for consumption as soon as it leaves the cell
· Easy: Simple installation and maintenance. Minimum space requirement
· Safe: No danger or way of overdosing, no addition of hazardous chemicals
· Versatile: Capacities available from 2 to 80 gallons per minute
· Economical: Hundreds of gallons of water can be purified for a few cents per day
· No Chemicals: No chlorine taste or corrosion problems






How Does UV Sterilisation Work?
 
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.


25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System




What Contaminants Do UV Sterilizers Remove? 
 
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%. 




 
CONVENTIONAL METHODS OF WATER TREATING
  CHLORINE OZONE ULTRA VIOLET
Capital cost Lowest High Low
Ease of installation Good Poor Excellent
Ease of Maintenance Good Poor Excellent
Cost of Maintenance Medium High Lowest
Operating Cost Low High Low
Frequency Of Maintenance Frequent Continuous V. Infrequent
Control System Poor Good Excellent
Virucidal Effect Good Poor Good
Toxic Chemical Yes Yes No
Residual Effect Problem with Yes Yes No
Hazards High Yes Low to none
Contact Time 30 - 60 minutes High 1 - 5seconds
Disinfection Performance Leaves some pathogens Kills all microbes Kills all microbes
Effect on Water Organochlorine compounds, Taste & pH changes Unknown None
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed.







Technical parameters:

model

capacity

Power

inlet-outlet

reactor

panel

Anchor

G weight

 

m³/hour

watt

mm

L×W×H

cm

screw

Kg

YLCn-005

0.3

16

1/2″

30×6×11

without

without

5

YLCn-008

1

25

1/2″

47×6.3×11

without

without

10

YLCn-050

2

40

1″

100×9×20

Φ8.9×25
(d×L)

69×4×Φ1

25

YLCn-150

6

80

1+1/4″

100×11×23

 

69×4×Φ1

30

YLCn-200

8

120

1+1/2″

100×15.9×30

Φ8.9×45
(d×L)

69×7×Φ1

35

YLCn-300

12

160

2″

100×15.9×32

 

69×7×Φ1

40

YLC-050

2

40

DN25/1″

100×8.9×30

25×30×12
(W×H×D)

60×4×Φ1

45

YLC-150

6

80

DN32/11/4″

100×10.8×30

 

60×4×Φ1

50

YLC-200

8

120

DN40/11/2″

100×15.9×40

 

60×7×Φ1

60

YLC-300

12

160

DN50/2″

100×15.9×40

 

60×7×Φ1

70

YLC-360

15

200

DN65/21/2″

100×15.9×40

 

60×7×Φ1

120

YLC-500

20

240

DN65/21/2″

100×21.9×50

 

60×11×Φ1.2

130

YLC-600

25

280

DN80/3″

100×21.9×50

 

60×11×Φ1.2

140

YLC-700

30

320

DN100/4″

100×21.9×50

 

60×11×Φ1.2

150

YLC-1000

40

360

DN100/4″

100×21.9×50

 

60×11×Φ1.2

160

YLC-1200

50

400

DN125/5″

100×21.9×50

 

60×11×Φ1.2

180

YLC-1500

60

420

DN150/6″

170×27.3×57

 

120×16×Φ1.4

210

YLC-2000

80

560

DN150/6″

170×27.3×57

 

120×16×Φ1.4

220

YLC-2500

100

700

DN150/6″

170×27.3×57

60×128×30
(W×H×D)

120×16×Φ1.4

275

YLC-3000

125

840

DN150/6″

170×27.3×57

 

120×16×Φ1.4

300

YLC-4000

150

1120

DN200/8″

173×32.5×65

 

120×20×Φ1.6

325

YLC-5000

200

1400

DN200/8″

173×37.7×72

 

120×22×Φ1.6

350

YLC-7000

300

2100

DN250/10″

175×42.6×80

 

120×24×Φ2.0

400

YLC-10K

400

2520

DN250/10″

176×52.9×95

60×150×40
(W×H×D)

120×22×Φ2.2

475

YLC-15K

600

3080

DN300/12″

176×78×110

 

120×32×Φ2.4

600

YLC-20K

800

3920

DN350/14″

Designated

Designated

Designated

Designated

YLC-25K

1000

4760

DN350/14″

Designated

Designated

Designated

Designated
 

25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System
25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System 25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System






 
Applications:
1. living water, drinking water, pure water and mineral water
2. swimming pool, landscape water, ciculating cooling water
3. food, cosmetic, medicine
4. sewage treatments
5. TOC reduction of electronic ultra-pure water
6. Aquarium

25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System






FAQ:



Is UV 100% effective? 
 
UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses. 
 
Does UV remove E. coli? 
 
Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system. 
 
How much does it cost to operate? UV systems are extremely economical to operate. 
 
A typical household UV system operates on the same power requirements as a 40 watt light bulb! 
 
Will UV change the taste or smell of my water? 
 
UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection. 
 
How do I know the system is working? 
 
All UV systems come with "lamp-out" monitors which give an audible and visual signal in case of lamp failure. Sterilight GOLD systems incorporate true UV intensity monitors so an alarm will sound if the disinfection effectiveness falls below a safe level. 
 
Why do I need Disinfection? 
 
Disinfection is required on all water supplies that are not protected by a municipal water source. Due to the uncertainties that exist within some water systems, we can no longer rely on the fact that our water supplies "may be safe." By providing your own disinfection, you are taking the responsibility of ensuring the safety of the water supply for you and your family.
25m3/H 280W Mual Cleaning UV Sterilizer Water Purification System

Send your message to this supplier

*From:
*To:
avatar Miss Mint Shi
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now