Pressure Sand Filters Cooling Tower Water Treatment Plant

Product Details
Customization: Available
Type: Niphos Water Filter
Usage: Environmental Protection
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
  • Pressure Sand Filters Cooling Tower Water Treatment Plant
Find Similar Products

Basic Info.

Model NO.
YLD-SF-2600
Motive Force
Pressure
Performance
Sophisticated Filters
Certification
CE
Name
Multimedia Filter
Flow Rate
30m3/H
Tank Size
2000*3100mm
Inlet and Outlet Diameter
Dn100mm
Active Carbon
1.2t
Working Pressure
0.6MPa/1.0 MPa
Control Mode
Automatic or Manual
Power Supply
Can Be Customized
Feature
Solid Particles Removal
Application
Waste Water and Industrial Water Treatment
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

 

Pressure Sand Filters System

Pressure Sand Filter remove non ionic impurities like clay, turbidity, dust, particles, heavy metals suspended solid matter etc. from water & wastewater. In pressure sand filter generally quartz sand is used for filtration supporting with gravels &pebbles ideal for sediment turbidity, sand, clay etc.

Our simple but well engineered media based filter acclaims stringent design, High performance , less pressure drop across the bed, longevity, optimum utilization of surface area ensure us to gain more and more clients' satisfaction..





Specification

  • Available in Vertical & Horizontal
  • Designed to meet the stringent requirements of clients
  • Filter up to 20 - 30 Microns
  • Well designed bed collection system
  • Operate in optimum velocity require
  • High removal of suspended solids.
  • Material of construction MS/FRP/MSRL/SS
  • Designed as per ASME or IS
  • Well designed distribution system
  • Well designed collection system
  • High end water quality

Pressure Sand Filters Cooling Tower Water Treatment PlantPressure Sand Filters Cooling Tower Water Treatment PlantPressure Sand Filters Cooling Tower Water Treatment PlantPressure Sand Filters Cooling Tower Water Treatment PlantPressure Sand Filters Cooling Tower Water Treatment Plant
Pressure Sand Filters Cooling Tower Water Treatment Plant
 

Application

  • Water treatment plant
  • Feed water of RO plant
  • Post treatment of wastewater treatment plant
  • Pretreatment of ion exchange based plant
  • Iron removal &Fluoride removal
  • Cooling tower water treatment plant.
  • Fountain, Water bodies and swimming pool
  • Rain water harvesting.
  • Gardening & washing application
  • River& lake water treatment.

 
 Most frequently used filtration fillings:
Fine gravel: 1-20mm
Silica sand of various roughness: 0.4-2.5mm
Active charcoal: is used for absorption of chlorine and other mineral substances
Anthracite: is used in two-layer or multi-layer filtration of drinking water in connection with sand - the addition of anthracite guarantees a longer filter lifetime, it facilitates a larger filtration through-flow and reduces sand contamination
Catalytic mediums [YAMLOX®]: are used to remove iron and manganese from drinking water
Semi-burnt Dolomite limestone: is used to reduce water acidity

The filtration bed can be formed by one layer or more layers of various filtration materials. Filtration sand lifetime during a proper washing of filters oscillates around 8 years on a standard basis.

Filters are controlled manually [with ball valves / shut-off valves] or automatically. In the case of an automatic filter control process, membrane or hydraulic or pneumatic valves are used.


The entire automatic process of filtration and back washing of filters is controlled by a central control unit. The control unit makes it possible to set filter washing on the basis of time, pressure difference or filtered water quantity.
 
Filters are washed, on a standard basis with raw water or with treated water from reservoirs.
 
Filters are fitted with a filtration inter-bottom with jets. The jets are made of the ABS material and make it possible to wash with water or both water and air. In the case of the filling height not exceeding 1500 mm, the water flushing process is fully sufficient.
 
Pressure filters are made of carbon steel with a protective anticorrosion coating with epoxy resin in the RAL 5010 [gentian blue] or 5012 [light blue] colour shade. The coating meets the conditions of hygienic harmlessness for contacts with drinking water. 




Technical Parameters:

  Specifications:

Model

TANK SIZE
(mm)

TOTAL HIGH
(mm)

FLOW RATE
(m3/hr)

INLET AND OUTLET
(mm)

YLD-MF-500

500*1500

2350

~2

DN32

YLD-MF-600

600*1500

2380

2-3

DN32

YLD-MF-700

700*1500

2400

~4

DN40

YLD-MF-800

800*1500

2400

~5

DN40

YLD-MF-900

900*1500

2500

~6

DN50

YLD-MF-1000

1000*1500

2600

~8

DN50

YLD-MF-1200

1200*1500

2700

~11

DN65

YLD-MF-1400

1400*1500

2800

~15

DN65

YLD-MF-1500

1500*1500

2850

~18

DN65

YLD-MF-1600

1600*1500

2900

~20

DN80

YLD-MF-1800

1800*1500
1800*1800

3000

~25

DN80

YLD-MF-2000

2000*1500

3100

~30

DN100

YLD-MF-2200

2200*1500

3180

~38

DN100

YLD-MF-2400

2400*1500

3330

~45

DN100

YLD-MF-2500

2500*1500

3380

~50

DN100

YLD-MF-2600

2600*1500

3430

~55

DN125

YLD-MF-2800

2800*1500

3530

~60

DN125

YLD-MF-3000

3000*1500

3630

70-80

DN125

YLD-MF-3200

3200*1500

3730

80~100

DN150

 

FAQ:
 
01.  how small a solid needs to be removed,
02.  how dirty the water is,
03.  how the water will be used once it is filtered,
04.  and the source of backwash water needed to clean the filters.




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier