Water Reclamation UV water sterilizer water purification
Ultraviolet Water Sterilizer Equipment is an efficient and rapid method of water disinfection without the use of heat or dangerous chemicals. Impact no taste or odor to water, it utilize germicidal ultraviolet light to quickly and reliably disable bacteria, viruses and other microorganisms present in water.
Inexpensive, Simple Operation, low operating cost and maximum efficiency make UV water sterilizer equipment suitable for a wide range of uses, it is providing quality water for:
? Drinking Water
? Hotels
? High Purity Water
? Hospital
? Food Process Water
? Cooling Towers
? Chemical
? Fish Hatcheries
? Fountains
? Sewage Treatments
? Electronic
? Water Reclamation
? Laboratories
? Cosmetics Manufacturers
? Bear Industry
? Bottled Water Suppliers
? Pharmaceutical
? Aquaculture & Hydroponic
Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.
Stainless Steel Germicidal Ultra Violet Light Systems Offer a Natural Approach to Purifying Water Without Toxic Chemicals
Heavy duty, high pressure leak resistant units makes these lights perfect on the budget for a high quality Stainless Steel unit.
Highly polished stainless steel interior They are polished to a high luster/shine inside the reactor chamber wall for improved reflection of the UV light thus allowing for more killing power.
Thermically-sensitive electronic ballast further protects our new UVC lamp, by automatically shutting down when the unit becomes too hot, preventing damage to both the lamp and the unit (Restarts automatically when it cools down)
Technical parameters:
model |
Processing capacity (Ton/Hour) |
power (W) |
inlet and outlet
(inch) |
working pressure (Kg/cm 2 ) |
malfunction alert for UV lamp |
reactor dimension (cm) L×W×H |
dimension of panel(cm) |
anchor bolt (cm) |
overall weight (Kg) |
YLCn-005 |
0.3 |
16 |
1/2" |
6 |
matched |
30×6×11 |
|
|
5 |
YLCn-008 |
1 |
25 |
1/2" |
6 |
matched |
47×6.3×11 |
|
|
10 |
YLCn-050 |
2 |
40 |
1" |
6 |
matched |
100×9×20 |
Φ8.9×25
(diameter×length) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4" |
6 |
matched |
100×11×23 |
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2" |
6 |
matched |
100×15.9×30 |
Φ8.9×45
(diameter×length) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2" |
6 |
matched |
100×15.9×32 |
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1" |
6 |
matched |
100×8.9×30 |
25×30×12
(L×H×w) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/1 1/4 " |
6 |
matched |
100×10.8×30 |
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/1 1/2 " |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2" |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/2 1/2" |
6 |
matched |
100×15.9×40 |
50×78×25
(L×H×W) |
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/2 1/2" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6" |
6 |
matched |
170×27.3×57 |
60×128×30
(W×H×T)
|
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6" |
6 |
matched |
173×27.3×57 |
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8" |
6 |
matched |
173×32.5×65 |
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8" |
6 |
matched |
173×37.7×72 |
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10" |
6 |
matched |
175×42.6×80 |
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10" |
6 |
matched |
176×52.9×95 |
60×150×40
(W×H×T) |
120×28×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12" |
6 |
matched |
176×78×110 |
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
confirmed |
YLC-25K |
1000 |
4760 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
Q. Does the water have to sit in the UV sterilizer to be disinfected?
A. No. If the system is sized correctly, the water is disinfected as it flows through.
Q. What if the water flows faster than is allowed through the system?
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded.
Q. How long does the lamp last?
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water.
Q. Are these systems bigger energy users?
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
Q. My water is sometimes cloudy. Is that a problem?
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated.