Sodium hypochlorite generator operation:
First manual will dissolve salt brine concentration box makes up 3-5% concentration (weight ratio) and high level, Start 103 meter saltwater brine pump adjusted 50L / h will be transported to the cell a drug brine overflow port shut to stop the brine pump 103, and then start adjusting the voltage to 18V rectifier current regulator in 150A (such as current reach enough dissolved salt concentration in the brine tank plus salt), while the rectifier start cooling water cooling cell electric valve open, the device work 10 minutes after opening the brine pump 103 to transport brine electrolyzer, the device can be converted into automatic mode, the device according to low level of sodium hypochlorite storage kits automatically open when a storage device to automatically stop the medicine chest high level, low level start automatically when sodium hypochlorite dosing pump out automatic dosing access signal according to the control room, a total of 100 hours of operation equipment need pickling time, the first pickling tank filled with dilute hydrochloric acid concentration of 3-5%, then the device will shut down the vent valve open cell inside the cell brine and then close the vent valve discharge all the high pickling tank flowmeter to 60L / h high level of investment and added to the cell and then close the valve acid, hydrochloric acid, and then soak for 15 minutes in the electrolyzer cell vent valve is opened to discharge all of hydrochloric acid, and then the cell inlet valve open 3 minutes before closing Finally, turn off the cell vent valve.
Technical Parameters:
A single active chlorine production: 500g/h
Power supply: 380V/50Hz 3 phase 4 wire
Working temperature: 0 ~ 40 º C
Mean annual humidity: 65%
Current efficiency: ≥ 50%
Dc power consumption: ≤ 7.0 kW· H/kg
Ac power consumption: ≤ 10.0 kW· H/kg
Salt consumption: ≤ 6.0 kg/kg
Available chlorine concentration: ≥ 8.0 g/L
Equipment noise: ≤ 75 dB(A)
The anode life strengthen the test of time: ≥ 10 hours
Chlorine concentration in the environment: <1.0 mg/ m
NO. |
Name |
specification |
Qty |
Note |
1 |
Brine ratio box |
1000*2000*1000 |
1 uint |
UPVC |
2 |
Brine tank |
1000*1000*800 |
1 unit |
UPVC |
3 |
Brine pumpo |
Q=1T/H |
1 unit |
|
4 |
sodium hypochlorite generator
|
800*600*1200 |
1 unit |
|
5 |
Rectifier cabinet |
800*600*1200 |
1 unit |
|
6 |
Electric control cabinet |
500*400*1200 |
1 unit |
|
7 |
Doing pump |
Q=35L/H |
1 unit |
|
8 |
Flow meter |
Q=50L/H |
1 piece |
|
9 |
Electric ball valve |
DN25 |
1 piece |
|
10 |
Electric ball valve |
DN20 |
1 piece |
|
11 |
exhaust fan |
N=0.37KW |
1 unit |
|
12 |
Pipe fittings |
DN40\DN20 |
1 set |
|