• Open Channel UV Water Sterilizer System with Automatic Control
  • Open Channel UV Water Sterilizer System with Automatic Control
  • Open Channel UV Water Sterilizer System with Automatic Control
  • Open Channel UV Water Sterilizer System with Automatic Control
  • Open Channel UV Water Sterilizer System with Automatic Control
  • Open Channel UV Water Sterilizer System with Automatic Control

Open Channel UV Water Sterilizer System with Automatic Control

Certification: ISO9001, CE
Application: Water Treatment
Voltage: 220V
Disinfection Method: Ultraviolet
Item: Open Channel UV Water Sterilizer System
Bactericidal Efficienc: 98% Kill Total Coliforms
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLD
Material
Stainless Steel Ss304, Ss316
Power
3200W
Lamps
10PCS*320W
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water
Watsewater, Municipal, Aquaculture Recirculating
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
842121999
Production Capacity
5000 Sets/Year

Product Description

Open Channel UV Water Sterilizer System With Automatic Control

Open channel UV water treatment systems are mainly used at the municipal water/wastewater treatment plants for water recycling and effluent disinfection to ensure a better level of environmental protection.

UV disinfection is an effective and environmentally friendly alternative to the conventional chlorine effluent disinfection. Nowadays more than 15% of 2000 waste water treatment plants in North America have chosen the UV as the primary disinfection method. UV disinfection has proved its safety, reliability, efficiency, and economical characteristics over the years.

 Open channel UV sterilziers GT series have been used for waste water, sewage water desinfection in order to achieve a lower envirionment pollution drainage.

Open Channel UV Water Sterilizer System with Automatic Control
Open Channel UV Water Sterilizer System with Automatic Control

Water quality factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution

Disinfection system factors that affect the disinfection efficiency and performance of the sewer UV treatment system

1. Hydrodynamic design of the sterilizer (Maximize the use of UV performance to increase the disinfector efficiency and reduce the water pressure loss

2. Lamp tube performance (including the system aging)

3. Arrangement of lamp tubes

4. Scale coefficient of lamp tubes

5. Performance of ballast

 

Design of the concise and lightweight bent frame

1. IP68 or equal grade of sealing protection. High-efficient secure multi-level sealing waterproof design.

2. The module adopts the push-in connectors with the less water resistance so as to guarantee the water incoming before disinfection and water discharge after disinfection.

3. There is little change in water level as to guarantee a stable sterilization effect.

4. It does not need any special tools to disassemble and assemble the disinfection module.
 

To customers details

Deatils:

01. What is the source of raw water to be treated?

 --is it underground water or well water?or river water ,other source?

02. What is the capacity(m3/hour) you required for this sterilizer?

 --most IMPORTANT requirement.

03. What will the treated water be used for?

--for human drinking or industry purpose?

04. What is the power supply in your country?
Open Channel sterilizer system specification
 

Capacity 320W lamp qty Model Note
M3/day Stand A Lamp power Stand B Lamp power Stand A Stand B Coefficient of variation
5000 24 7.68 16 5.12 YLD-320W-3-8 YLD-320W-4-4 K= 1.3
10000 36 11.52 24 7.68 YLD-320W-4-9 YLD-320W-3-8 K=1.3
15000 56 17.92 32 10.24 YLD-320W-7-8 YLD-320W-4-8 K=1.3
20000 64 20.48 48 15.36 YLD-320W-8-8 YLD-320W-6-8 K=1.3
25000 80 25.6 56 17.92 YLD-320W-10-8 YLD-320W-7-8 K=1.3
30000 96 30.72 64 20.48 YLD-320W-12-8 YLD-320W-8-8 K=1.3
35000 100 32 80 25.6 YLD-320W-10-10 YLD-320W-10-8 K=1.3
40000 120 38.4 88 28.16 YLD-320W-12-8 YLD-320W-11-8 K=1.3
50000 160 51.2 96 30.72 YLD-320W-20-8 YLD-320W-12-8 K=1.3
60000 208 66.56 128 40.96 YLD-320W-26-8 YLD-320W-16-8 K=1.3
80000 230 73.6 152 48.64 YLD-320W-23-10 YLD-320W-19-8 K=1.3
100000 256 81.92 160 51.2 YLD-320W-32-8 YLD-320W-20-8 K=1.3
150000 300 96 240 76.8 YLD-320W-3-8 YLD-320W-24-8 K=1.3
180000 320 102.4 300 96 YLD-320W-3-8 YLD-320W-25-8 K=1.3
200000 360 115.2 320 102.4 YLD-320W-30-12 YLD-320W-40-8 K=1.3
Application:Open Channel UV Water Sterilizer System with Automatic Control
Typical Applications Wide range of clean / waste water treatment
Lamp Type Low-pressure, high-efficiency amalgam (monochromatic)
Ballast Type Electronic, high-efficiency, variable output (60~100% power)
Input Power Per Lamp 320, 550 Watts/pc
Lamp Configuration Horizontal, parallel to flow; Vertical to flow; 65°with the folow
Lamp Brand & Origin Lightsource/Philip/Heraeus/Domestic brand
Module Configuration 8, 10 or 12 lamps per module
Level Control Device Options Automatic Level Controller, Fixed weir or motorized weir gate
Water Level Sensor 1 electrode low water level sensor per channel
UV Intensity Sensor 1 UV detector for one sterilizer module
Working Temperature 4~60ºC/39.2~140ºF
Working Pressure 6 bar / 100psi
Enclosure Ratings
Module Frame/Ballast Enclosure TYPE 6P (IP68) / TYPE 6P (IP67)
All Other Enclosures TYPE 4X (IP56)
Ballast Cooling Method Convection / Air conditioning / Forced air required
Installation Location Indoor or outdoor
Module Frame/Chamber SS304/SS316, Internal finish - Ra(max)0.8um
Sleeve Cleaning System
Auto-Cleaning System Automatic Chemical/Mechanical (optional)
Auto-Cleaning WW Gel Non-corrosive, operator-friendly, food-grade
Sleeve Spec Quartz sleeves, UV transmittance >92%
Controller PLC-based (Siemens/ Schneider PLC Standard Platform)
Electrical Requirements
Power Supply 220V, 50Hz (can be customized )
Electrical Cabinet Working temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)
Projects:

Open Channel UV Water Sterilizer System with Automatic Control
Open Channel UV Water Sterilizer System with Automatic Control
Our Services

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
Mobile phone: +86 13585066069
 

 
Alibaba website: http://yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year
After-sale service:800-827-87-226


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now