• Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
  • Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
  • Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
  • Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
  • Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
  • Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System

Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System

Type: Condenser Cleaning Device
Usage: Environmental Protection
Motive Force: Electric power
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System pictures & photos
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
US $3,500 / Piece
Min. Order: 1 Piece
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Installation Instructions
  • Our Advantages
  • After Sales Service
  • Certifications
Overview

Basic Info.

Model NO.
DN200
Style
Vertical
Performance
Tube Cleaning Device
Certification
CE, GS
Item
Continuous Condenser/ Chiller Tube Cleaning System
Inlet and Outlet
8 Inch
Working Pressure
0.2-1.6MPa
Cleaning Ball
Rubber, Diamond
Flow Rate
≥16L/S
Water Pump Head
≥ 20m
Ball Catcher Resistance
<0.5m
Power
1.5 Kw
Boiling Tube Diameter
2 Inch
Application
Air Conditioning, Heat Exchange, Condenser
Transport Package
Plywood Case Packaged Into Container
Specification
to be practical
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
30 Sets/Month

Packaging & Delivery

Package Size
120.00cm * 100.00cm * 120.00cm
Package Gross Weight
80.000kg

Product Description

 
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
 
Product Description

 

How it Works?
YLD uses the same hydraulic principles as classical condenser tube cleaning systems of injecting elastomeric sponge rubber balls into the cooling water supply inlet. The cooling water pushes the sponge balls into the condenser tubes, beginning the circulating process. The sponge balls have a diameter that is slightly larger than the tube inner diameter, which allows them to have constant contact with the tube walls. This allows the sponge balls to scrub and sweep the tubes as they move through them.
The difference is found in the innovative ball strainer design. This system ensures that no sponge balls will be released into sensitive marine environments or cooling water towers. The Beaudrey system has been designed to be operator friendly and easy to maintain.
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
                                       Before using                                                                     After using


Value Creating Advantages
1. 100% ball recovery guarantee makes the most environmentally friendly condenser tube cleaning system available today
2. No release of lubricants to marine environments
3. Decrease heat rate and increase reliability
4. Eliminate forced outages and unit de-ratings
5. Simple maintenance-designed to be overhauled in one shift
6. Reduction in tube corrosion caused by micro-fouling and scaling; condenser tubes maintain their original cleanliness
7. Reduction in the expenditure of re-tubing of condensers by drastically extending their lifecycle
8. YLD design principle allows for spare part interchangeability with debris filter and Water Intake Protection Screen 
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
   Balls through pump condenser ball cleaning device            PLC balls not through pump condenser ball cleaning device



Problem: Tube Micro-Fouling
As cooling water is circulated through condenser or heat exchanger tubes it can leave behind silt, sand, mud, soluble elements (calcium carbonate, calcium silicate, magnesium chloride, etc.) or bacteria. When these substances settle or crystallize in the condenser tubes, they cause scaling or tube-fouling which lowers turbine, condenser and heat exchanger efficiency. As efficiency in condensers and heat exchangers decreases, the thermal cycle is directly impacted, causing an increase in heat rate. In some cases, tube micro-fouling can cause condenser tube corrosion, pitting and failure. This can lead to contamination of the circulating de-mineralized water by the intake water used for cooling, ultimately resulting in boiler and turbine damage.
Before the emergence of continuous condenser tube cleaning technology, systems would be either chemically cleaned or they would have to be taken off-line for manual maintenance and cleaning. Chemical cleaning is hazardous for workers and extremely detrimental to the environment. The down time associated with manual condenser cleaning halts production and de-rates power plant output, translating into lost profits for power plants.
Product Parameters

Technical Parameters

Model Inlet/Outlet size
(mm)
Main machine size
L*W*H(mm)
Ball Collector size
D*H(mm)
YL-CS100 DN100/ 4 inch 850*600*1200 100*400
YL-CS125 DN125/ 5 inch 850*600*1200 125*500
YL-CS150 DN150/ 6 inch 850*600*1200 150*600
YL-CS200 DN200/ 8 inch 850*600*1200 200*800
YL-CS250 DN250/ 10 inch 850*600*1200 250*900
YL-CS300 DN300/ 12 inch 850*600*1200 300*1200
YL-CS350 DN350/ 14 inch 850*600*1200 350*1400
YL-CS400 DN400/ 16 inch 850*600*1200 400*1800
Packaging & Shipping
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System

 

Installation Instructions
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System

 

 

Our Advantages

 


? We are the water treatment manufacturer in China.look forward to your arrival and we will lead you to visit our factory

? Find our products through our website or cellphone call or whatsApp or skype or email

? One year warranty for the whole system .
? After one year , we can help you to maintain the machine and the accessories are provided only one the cost price.
? Track the order until you get the goods.
? We value every inquiry sent to us, ensure quick competitive offer.
? Update you latest price any time
After Sales Service

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
 
Website: http://yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year
 

Certifications
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System
Zero Ball Loss Continuous Condenser/ Chiller Tube Cleaning System

Send your message to this supplier

*From:
*To:
avatar Miss Mint Shi
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now