Salt Water Softening Filter with Regeneration and Backwash Valve

Product Details
Customization: Available
Installation: Vertical Type
Working Principle: Ion Exchange
Still deciding? Get samples of US$ 1300/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Salt Water Softening Filter with Regeneration and Backwash Valve
  • Salt Water Softening Filter with Regeneration and Backwash Valve
  • Salt Water Softening Filter with Regeneration and Backwash Valve
  • Salt Water Softening Filter with Regeneration and Backwash Valve
  • Salt Water Softening Filter with Regeneration and Backwash Valve
  • Salt Water Softening Filter with Regeneration and Backwash Valve
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Installation Instructions
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • After Sales Service
  • Company Profile
Overview

Basic Info.

Model NO.
YL-I-6
Inlet Mode
Pipeline
Heating Mode
Instant Heat
Water Hardness of Raw Water
<8mmol/L
Turbidity of Raw Water
<5ntu
Water Output
<0.03mmol/L
Working Pressure
0.2-0.4MPa
Control for Regeneration
Flow Rate Based Control
Working Temperature
5 to 50 Centigrade
Free Chlorine
<0.5mg/L
Water Temperature
5-45 Centigrade
Iron Content
<0.3mg/L
Suspended Solid
<0.5mg/L
Transport Package
Plywood Case Into Container
Specification
refer to parameters sheet or to be customized
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
100 Units/Month

Packaging & Delivery

Package Size
195.00cm * 65.00cm * 65.00cm
Package Gross Weight
300.000kg

Product Description

Salt  Water Softening Filter With Regeneration And Backwash Valve
 
Product Description

 Principles of Ion Exchange to Soften Water


Calcium and magnesium ions are atoms having a positive electrical charge, as do sodium and potassium ions. Ions of the same charge can be exchanged. In the ion exchange process, a granular substance (usually a resin) that is coated with sodium or potassium ions comes into contact with water containing calcium and magnesium ions. Two positively charged sodium or potassium ions are exchanged (released into the water) for every calcium or magnesium ion that is held by the resin. This "exchange or trade" happens because sodium or potassium are loosely held by the resin. In this way, calcium and magnesium ions responsible for hardness are removed from the water, held by the resin, and replaced by sodium or potassium ions in the water. This process makes water "soft." Eventually, a point is reached when very few sodium or potassium ions remain on the resin, thus no more calcium or magnesium ions can be removed from the incoming water. The resin at this point is said to be "exhausted" or "spent," and must be "recharged" or "regenerated."
Ion Exchange Unit Components
A water softener can be as simple as a tank to hold the exchange resin, together with appropriate piping for raw (inlet) and treated (outlet) water. Modern water softeners include a separate tank for the brine solutions used to regenerate the resin, additional valves to back-wash the resin, and switches for automatic operation.
Plumbing Requirements
New homes are plumbed for water softeners. Plumbing old homes for soft water can be very expensive. Not all the water coming into a home needs treatment. If the water is classified as very hard (10.5 or more grains per gallon or 180 or more mg/L of calcium carbonate), a house point-of-entry (POE) treatment may be needed. Otherwise, only the hot water supply should be treated to reduce formation of calcium deposits (scale) in the water heater and pipes.
Personal preference may also influence the decision to treat hot and cold supplies going to the laundry room, showers, and sinks. Toilets and outdoor faucets should not receive softened water. Softened and untreated water may also be "blended" to produce water with a lower hardness and to decrease the amount of water that must be treated.
Salt Water Softening Filter with Regeneration and Backwash Valve
Unit Selection

The selection of a water softening unit depends on the hardness of the raw water and the amount of water to be softened. There are manual, automatic, semiautomatic, and fully automatic units that differ in the degree of resin regeneration automation. First, the number of fixtures in the home that will require softened water must be determined. Then, all the fixtures' flow rates need to be added up. Note that conventional faucets use 3-5 gallons per minute (gpm) and conventional showers use 5-10 gpm. (Newer, water-saving fixtures may use only half these amounts.)
Working configuration:singe-valve and dual-tank,one tank is working,the other tank is standby,alternative regeneration for continuous 24 hours working.
 
01. By means of Absorbing the calcium and magnesium ions in water with resin, since the hardness of water is mainly composed of calcium and magnesium, in general, we adopt cation exchange resin (softener), replace Ca2+, Mg2+ (main ingredients for scale) in water, as the increase of Ca2+ and Mg2+ in resin, removing performance on Ca2+, Mg2+ of resin will gradually reduce.

02. When the resin has absorbed a certain amount of calcium and magnesium ions, it must be regenerated, the regeneration process is that flush resin layer with the salt water in salt box, replace hardness ion out of the resin again, and discharged from the tank with waste liquid of regeneration, then resin resumed the function of softening and exchanging.

03. The principle of sodium ion exchange and softening treatment is to exchange cation in the raw water with resin, hardness constituents Ca2+and Mg2+ in water exchange Na+ in resin, thus absorb the Ca2+and Mg2+ to make the water to be softened.
2RNa + Ca2+ = R2Ca + 2Na+
2RNa + Mg2+ = R2Mg + 2Na+
After the water treated by sodium ion exchanger, the Ca+ and Mg+ were superseded by Na +.


Application scope of softener
Mainly used in industry and civil water softening preparation, such as Boiler feed water make-up water, air conditioning system make up water, heat exchanger, power plant, chemical, textile, printing and dyeing, bio-pharmaceutical, Electronic system and water pretreatment.


 
Detailed Photos
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
Installation Instructions

 

 
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve

 

Product Parameters
AAA:

 01.What is the capacity(cubic meter per hou)for this water softener?--VERY IMPORTNT for our quotation.
 
02.What is the working hours for this water softner each day?is it continuous 24 hours working or not?
 
03.Do you require the whole water softener system be assembed and installed into an integrated compact cabinet?
04.if there is no special requirement on valve brand,we will choose top domestic brand valve,
 

Type
 
   Model Water Output
(m³/hour)
Resin-tank<mm>
(diameter*Height)
Brine-tank(Liter) Resin
(kg)





Single Valve Single Tank
YL-I-0.5 0.5 200×900×1PC 60×1PC 20
YL-I-1 1 250×1400×1PC 60×1PC 40
YL-I-2 2 300×1400×1PC 100×1PC 60
YL-I-3 3 350×1400×1PC 130×1PC 80
YL-I-4 4 400×1650×1PC 200×1PC  120
YL-I-5 5 500×1750×1PC 300×1PC  180
YL-I-6 6 600×1900×1PC 350×1PC  240
YL-I-10 10 750×1900×1PC 500×1PC 360
YL-I-18 18 900×1900×1PC 800×1PC 520
YL-I-25 25 1000×2200×1PC 1000×1PC 720
YL-I-35 35 1200×2400×1PC 1500×1PC 1000
YL-I-50 50 1500×2500×1PC 2000×1PC 1600

Dual Valve Dual Tank
(Simultaneous working, alternate regeneration)
YL-II-36 36 900×1900×2PCS 800×2PCS 1040
YL-II-50 50 1000×2200×2PCS 1000×2PCS 1440
YL-II-70 70 1200×2400×2PCS 1500×2PCS 2000
YL-II-100 100 1500×2500×1PCS 2000×2PCS 3200




Dual Valve Dual Tank
(One work, one standby)
YL-II -1 1 250×1400×2PCS 60×2PCS 80
YL-II-2 2 300×1400×2PCS 100×2PCS 120
YL-II-3 3 350×1400×2PCS 130×2PCS 160
YL-II-4 4 400×1650×2PCS 200×2PCS  240
YL-II-5 5 500×1750×2PCS 300×2PCS  360
YL-II-6 6 600×1900×2PCS 350×2PCS  480
YL-II-10 10 750×1900×2PCS 500×2PCS 720
YL-II-18 18 900×1900×2PCS 800×2PCS 1040
YL-II-25 25 1000×2200×2PCS 1000×2PCS 1440
YL-II-35 35 1200×2400×2PCS 1500×2PCS 2000
YL-II-50 50 1500×2500×2PCS 2000×2PCS 3200
Certifications
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
Packaging & Shipping
Salt Water Softening Filter with Regeneration and Backwash Valve
Salt Water Softening Filter with Regeneration and Backwash Valve
 
After Sales Service

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
 
Website: http://yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year

Company Profile

Development History:
2000: Jiangyin YLD was founded.
2004:Jiangyin YLD change to Jiangsu YLD, registered fund from 50 ten thousand to 500 million, factory area from 1500m2 to 15000 m2.
2005: From 2005 year to now, every year credit rating was awarded "AAA" .
2007: Jiangyin science and technology bureau granted YLD "JIANGYIN ENGINEERING AND RESEARCH CENTER FOR WATER FILTER AND ULTRAVIOLET STERILIZAT
2009: Open the foreign market, the products were sold abroad, Canada, USA, Singapore and so on.
2010: YLD Trademark was registered successful.
2012: The formal establishment of the ministry of foreign trade opened up more foreign markets.
2014: Patented by many products independently researched and developed by the company.
2015: The self-developed multi-cartridge automatic backwash filter was rated as a high-tech product and obtained a certificate.
2016: The company was rated as a scientific and technological enterprise and a high-tech enterprise in Jiangsu Province.
2019: The company got "Manufacture License of Special Equipment People's Republic of China".
2020: Awarded the title of "Loving Enterprise" by the government and "Quality Supplier" by suppliers
2021: Got the new certificater: Disinfection enterprse health license. 
Salt Water Softening Filter with Regeneration and Backwash Valve


 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now