• Sand Filter Tank Water Treatment
  • Sand Filter Tank Water Treatment
  • Sand Filter Tank Water Treatment
  • Sand Filter Tank Water Treatment
  • Sand Filter Tank Water Treatment
  • Sand Filter Tank Water Treatment

Sand Filter Tank Water Treatment

Type: Activated Carbon
Usage: Environmental Protection
Motive Force: Pressure
Style: Vertical
Performance: Sophisticated Filters
Certification: CE
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLD-SF-1400
Quality Authentication
ISO9001:2008
CE Authentication
CE
Material for Filtration Tank
Stainless Steel/ Carbon Steel
Material for Face Piping
Stainless Steel or PVC
Input Power
2~20kw
Power Supply
AC380V 35A 50Hz
Flow Rate
45~75 M3/H
Inlet and Outlet Diameter
4 Inch
Control Mode
Automatic or Manual
Filter Area
1.54m2
Transport Package
Plywood Case Into Container
Specification
CE, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu, China
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

Product Introduction
By-pass filter for chilled water as a by-pass filtering equipment of closed industrial circulating water is used to filter the circulating chilled water and its control modes consist of manual backwash and automatic backwash. The system is generally backwashed once every three to seven days in the circulating process, effectively improving the quality of chilled water and ensuring excellent and stable water quality after intervention to long-term running. The device has small water consumption and is widely used in the cleaning of all types of industrial and commercial chilled water circulation system as well as refrigerant water and heat medium water systems of central air conditioning, improving the stability of equipment operation. Users may weld and conned in parallel the by-pass filters in main return pipes depending on the conditions of circulation system and the pipe diameter should be determined based on the retaining water yield of parallel circulating water. The sewage water is then discharged into the sewerage network.
 
Working principle
For the by-pass filtration, the filter is installed in the main circulating pipeline to filter all the circulating water, but a part of the circulating water led from the main circulating pipeline is filtered, which is a repeated circulating interception step by step to filter the impurities within the system and finally remove the impurities by the necessary backwash out of the system. Installing a by-pass filter in the circulating water system can prevent the terminal pipe of device from sludge blocking and remove the impurities in the system with chemical dosing.
By-pass filtration is used to reduce the turbidity of the water circulation system, exactly, to reduce slime and prevent its deposition in the heat exchanger, so that the effect of agent will be better.
 
 
Generally speaking, if your filter is a quartz sand filter, it usually has two main functions:
1. To reduce suspended solids (turbidity). Otherwise, as the system is running, suspended solids increases, which will exacerbate the deposition and other problems.
2. Degreasing. Especially the oily turbid circulation, such as steel rolling and continuous casting, has high oil content and is easy for breeding microorganism and blocking the nozzles.
 
Technical description of by-pass filter for the industrial circulating water
Flow filter flow is designed according to 5% to 10% of the total circulation volume (the by-pass filter flow of the cooling water is designed by 10 % of the circulation volume and the by-pass filter flow of chilled water is designed by 5% of the circulation volume) and the filtration rate is designed by 20 - 3Smih according to water quality of the system. Specific to corrosive suspended solids of the circulating water system as well as the control, our technical support team has designed a variety of manual/automatic by-pass filtrating equipment in line with customer demand.
 




Product Features:
 
Shallow filter filtration system uses a modular design, based on traffic, covering, etc., can be flexibly combined. The system can be used, pressure a variety of ways to start automatically backwash, fully automatic operation. Each filter unit in the system sequentially backwashing is not interrupted when the backwash effluent.
 
Automatic control of the filtration system is modular in design, according to the size of the flow, a plurality of filter units.
Can be used, pressure, etc. a variety of ways to start automatically backwash the filter unit in the system are backwashed, the other unit is still in the filter.
 
The high recoil efficiency, recoil a short time, the backwash water conservation (backwash water consumption rate is less than 1%).
 
Small footprint, and the flexibility to design the arrangement of the filter unit according to the actual land.
 
The system is lightweight and does not require special base concrete floor can.
 
All-plastic system, good corrosion resistance.
 
ASM filter, has a better resistance to bacterial contamination, the backwash better.
 
Shallow filters system is lightweight and does not require an ad hoc basis, a general concrete floor system covers an area of small, flexible arrangement according to the actual situation, easy to install.
 
The shallow filter filtration system can be applied to a variety of water treatment industry, such as water supply and filtration treatment, cooling circulating water filter and next to the filter, wastewater treatment and reuse, and so on, is an alternative to traditional sand filters, valveless preferred.





Technical parameters:
 

Model

Tank size
(D)*(H)

Inlet and outlet
(mm)

Filter area
(mm)

FLOW RATE
(m3/hr)

YLD-SF-800

800*960mm

50

0.5

15-25

YLD-SF-1000

1000*1200mm

50

0.79

23-39

YLD-SF-1200

1200*1400mm

80

1.13

33-55

YLD-SF-1400

1400*1600mm

100

1.54

45-75

YLD-SF-1600

1600*1800mm

100

2.01

60-100

YLD-SF-1800

1800*1950mm

150

2.54

75-125

YLD-SF-2000

2000*2150mm

150

3.14

95-155

YLD-SF-2200

2200*2250mm

150

3.80

115-190

YLD-SF-2400

2400*2300mm

150

4.52

130-210

YLD-SF-2600

2600*2400mm

150

5.30

145-225

YLD-SF-2800

2800*2500mm

200

6.15

155-240

YLD-SF-3000

3000*2600mm

200

7.00

170-255

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now