Ultraviolet Lamp Disinfection System Water Purifying

Product Details
Customization: Available
Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Ultraviolet Lamp Disinfection System Water Purifying
  • Ultraviolet Lamp Disinfection System Water Purifying
  • Ultraviolet Lamp Disinfection System Water Purifying
  • Ultraviolet Lamp Disinfection System Water Purifying
  • Ultraviolet Lamp Disinfection System Water Purifying
  • Ultraviolet Lamp Disinfection System Water Purifying
Find Similar Products

Basic Info.

Model NO.
YLC-4000
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 Mpa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
842121999
Production Capacity
5000 Sets/Year

Product Description

Ultraviolet Lamp Disinfection System Water Purifying
Specifications:
Ultraviolet Lamp Disinfection System Water Purifying
Ultraviolet Lamp Disinfection System Water Purifying
Detailed Product Description
Ultraviolet Sterilizers Efficiency
1. High bacterial efficiency
2. Low cost.

FAQ:
01.What is the source of raw water to be treated?
--is it underground water or well water?or river water ,other source?
02.What is the capacity(m3/hour) you required for this sterilizer?
--most IMPORTANT requirement.
03.What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
--220V 50Hz?
Ultraviolet Lamp Disinfection System Water PurifyingUltraviolet Lamp Disinfection System Water Purifying
Application
1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10. Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
12. Agricultural water disinfection

Product application
Ultraviolet light treatment is a widely recognized and proven method of disinfection of water and has several advantage over other disinfection methods such as chlorination, ozonation, etc. UV light does not add anything to the water, such as, undesirable color, odor, taste, or flavor, nor does it generate harmful byproducts. It adds only energy in the UV radiation. Also, UV disinfection requires only a fraction of the contact times required by other disinfection methods. It is fast, efficient, effective, economical and environmentally-friendly.

Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.


Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)

DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
Ultraviolet Lamp Disinfection System Water Purifying
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
Ultraviolet Lamp Disinfection System Water Purifying

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier