Ss304 Reactor Wastewater Ultraviolet Water Sterilizer

Product Details
Customization: Available
Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
Find Similar Products

Basic Info.

Model NO.
YLC-1500
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

SS304 Reactor Wastewater Ultraviolet Water Sterilizer

Advantages:
UV light will kill any DNA based micro organism when give enough UV dosage.
UV break micro organism's DNA in a cumulative basis.
Continuous disinfection in cooling water. If micro organism is not effectively deactivated on the first disinfection cycle and in the next cycle it get UV treated.
For 90% kill algae 30000 μWs/cm2 is required for one cycle .
UV spectrum between 185-400nm has a strong germicidal effect, with peak effectiveness at 265nm.
UV works instantaneously against all water-borne microorganisms, including bacteria, viruses, molds, spores and protozoa - including those resistant to chlorine.
UV systems are also very easy to use and can be effectively monitored and integrated with online process control systems.
UV disinfection systems are very compact, modular and easy to 
install into existing water treatment systems.
UV does not cause the formation of chemical disinfection by-
products, many of which can have undesired effects of their own.
UV sterilizer is eco-friendly and cost effective.
 
UV Disinfection Systems Application
1. Food processing and industrial water disinfection
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
3. Municipal water
4. Biochemical pharmaceutical, cosmetics production water disinfection
5. Aquatic products processing water disinfection
6. Swimming pool water disinfection
7. Seawater, freshwater aquaculture breeding water disinfection
8. Ultra-pure water for electronic industry, and so on

Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.


Stainless Steel Germicidal  Ultra Violet Light Systems Offer a Natural Approach to Purifying Water Without Toxic Chemicals 
Heavy duty, high pressure leak resistant units makes these lights perfect on the budget for a high quality Stainless Steel unit.
Highly polished stainless steel interior They are polished to a high luster/shine inside the reactor chamber wall for improved reflection of the UV light thus allowing for more killing power.
Thermically-sensitive electronic ballast further protects our new UVC lamp, by automatically shutting down when the unit becomes too hot, preventing damage to both the lamp and the unit (Restarts automatically when it cools down)



Technical parameters:
model Processing capacity (Ton/Hour) power (W)  inlet and outlet
(inch)
working pressure (Kg/cm 2 ) malfunction alert for UV lamp reactor dimension (cm) L×W×H dimension of panel(cm) anchor bolt  (cm) overall weight (Kg)
YLCn-005 0.3 16 1/2" 6 matched 30×6×11     5
YLCn-008 1 25 1/2" 6 matched 47×6.3×11     10
YLCn-050 2 40 1" 6 matched 100×9×20 Φ8.9×25
(diameter×length)
69×4×Φ1 25
YLCn-150 6 80 1+1/4" 6 matched 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2" 6 matched 100×15.9×30 Φ8.9×45
(diameter×length)
69×7×Φ1 35
YLCn-300 12 160 2" 6 matched 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1" 6 matched 100×8.9×30 25×30×12
(L×H×w)
60×4×Φ1 45
YLC-150 6 80 DN32/1 1/4 " 6 matched 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/1 1/2 " 6 matched 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2" 6 matched 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/2 1/2" 6 matched 100×15.9×40 50×78×25
(L×H×W)
60×7×Φ1 120
YLC-500 20 240 DN65/2 1/2" 6 matched 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3" 6 matched 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5" 6 matched 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6" 6 matched 170×27.3×57 60×128×30
(W×H×T)
 
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6" 6 matched 173×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8" 6 matched 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8" 6 matched 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10" 6 matched 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10" 6 matched 176×52.9×95 60×150×40
(W×H×T)
120×28×Φ2.2 475
YLC-15K 600 3080 DN300/12" 6 matched 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14" 6 matched confirmed  confirmed confirmed confirmed
YLC-25K 1000 4760 DN350/14" 6 matched confirmed confirmed confirmed


FAQ
Q. Does the water have to sit in the UV sterilizer to be disinfected? 
A. No. If the system is sized correctly, the water is disinfected as it flows through. 
 
Q. What if the water flows faster than is allowed through the system? 
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded. 
 
Q. How long does the lamp last? 
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water. 
 
Q. Are these systems bigger energy users? 
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
 
Q. My water is sometimes cloudy. Is that a problem? 
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated. 
 