Ss304 Reactor Wastewater Ultraviolet Water Sterilizer

Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Medium Material: PP (Propene Polymer)
Lifespan of UV Lamp: 9000-12000 Hours
Interface Type: Flange or Thread
Flow Rate: 0.3--1000 Ton/Hour
Customization:

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YLC-1500
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

SS304 Reactor Wastewater Ultraviolet Water Sterilizer

Advantages:
UV light will kill any DNA based micro organism when give enough UV dosage.
UV break micro organism's DNA in a cumulative basis.
Continuous disinfection in cooling water. If micro organism is not effectively deactivated on the first disinfection cycle and in the next cycle it get UV treated.
For 90% kill algae 30000 μWs/cm2 is required for one cycle .
UV spectrum between 185-400nm has a strong germicidal effect, with peak effectiveness at 265nm.
UV works instantaneously against all water-borne microorganisms, including bacteria, viruses, molds, spores and protozoa - including those resistant to chlorine.
UV systems are also very easy to use and can be effectively monitored and integrated with online process control systems.
UV disinfection systems are very compact, modular and easy to 
install into existing water treatment systems.
UV does not cause the formation of chemical disinfection by-
products, many of which can have undesired effects of their own.
UV sterilizer is eco-friendly and cost effective.
 
UV Disinfection Systems Application
1. Food processing and industrial water disinfection
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
3. Municipal water
4. Biochemical pharmaceutical, cosmetics production water disinfection
5. Aquatic products processing water disinfection
6. Swimming pool water disinfection
7. Seawater, freshwater aquaculture breeding water disinfection
8. Ultra-pure water for electronic industry, and so on

Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.


Stainless Steel Germicidal  Ultra Violet Light Systems Offer a Natural Approach to Purifying Water Without Toxic Chemicals 
Heavy duty, high pressure leak resistant units makes these lights perfect on the budget for a high quality Stainless Steel unit.
Highly polished stainless steel interior They are polished to a high luster/shine inside the reactor chamber wall for improved reflection of the UV light thus allowing for more killing power.
Thermically-sensitive electronic ballast further protects our new UVC lamp, by automatically shutting down when the unit becomes too hot, preventing damage to both the lamp and the unit (Restarts automatically when it cools down)



Technical parameters:
modelProcessing capacity (Ton/Hour)power (W) inlet and outlet
(inch)
working pressure (Kg/cm 2 )malfunction alert for UV lampreactor dimension (cm) L×W×Hdimension of panel(cm)anchor bolt  (cm)overall weight (Kg)
YLCn-0050.3161/2"6matched30×6×11  5
YLCn-0081251/2"6matched47×6.3×11  10
YLCn-0502401"6matched100×9×20Φ8.9×25
(diameter×length)
69×4×Φ125
YLCn-1506801+1/4"6matched100×11×2369×4×Φ130
YLCn-20081201+1/2"6matched100×15.9×30Φ8.9×45
(diameter×length)
69×7×Φ135
YLCn-300121602"6matched100×15.9×3269×7×Φ140
YLC-050240DN25/1"6matched100×8.9×3025×30×12
(L×H×w)
60×4×Φ145
YLC-150680DN32/1 1/4 "6matched100×10.8×3060×4×Φ150
YLC-2008120DN40/1 1/2 "6matched100×15.9×4060×7×Φ160
YLC-30012160DN50/2"6matched100×15.9×4060×7×Φ170
YLC-36015200DN65/2 1/2"6matched100×15.9×4050×78×25
(L×H×W)
60×7×Φ1120
YLC-50020240DN65/2 1/2"6matched100×21.9×5060×11×Φ1.2130
YLC-60025280DN80/3"6matched100×21.9×5060×11×Φ1.2140
YLC-70030320DN100/4"6matched100×21.9×5060×11×Φ1.2150
YLC-100040360DN100/4"6matched100×21.9×5060×11×Φ1.2160
YLC-120050400DN125/5"6matched100×21.9×5060×11×Φ1.2180
YLC-150060420DN150/6"6matched170×27.3×57120×16×Φ1.4210
YLC-200080560DN150/6"6matched170×27.3×57120×16×Φ1.4220
YLC-2500100700DN150/6"6matched170×27.3×5760×128×30
(W×H×T)
 
120×16×Φ1.4275
YLC-3000125840DN150/6"6matched173×27.3×57120×16×Φ1.4300
YLC-40001501120DN200/8"6matched173×32.5×65120×20×Φ1.6325
YLC-50002001400DN200/8"6matched173×37.7×72120×22×Φ1.6350
YLC-70003002100DN250/10"6matched175×42.6×80120×24×Φ2.0400
YLC-10K4002520DN250/10"6matched176×52.9×9560×150×40
(W×H×T)
120×28×Φ2.2475
YLC-15K6003080DN300/12"6matched176×78×110120×32×Φ2.4600
YLC-20K8003920DN350/14"6matchedconfirmed confirmedconfirmedconfirmed
YLC-25K10004760DN350/14"6matchedconfirmedconfirmedconfirmed


FAQ
Q. Does the water have to sit in the UV sterilizer to be disinfected? 
A. No. If the system is sized correctly, the water is disinfected as it flows through. 
 
Q. What if the water flows faster than is allowed through the system? 
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded. 
 
Q. How long does the lamp last? 
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water. 
 
Q. Are these systems bigger energy users? 
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
 
Q. My water is sometimes cloudy. Is that a problem? 
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated. 
 

Send your message to this supplier

*From:
*To:
avatar Miss Mint Shi
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now