Submersible uv lamp water sterilizer
Overview
The integrated or ballast external profile includes: Quartz UV bactericidal lamps, quartz tubes, sealing accessories, four-hole plug. Rubber cap, protection and indicator lights and external electronic ballast. The bactericidal lamps can dive into the water and realize 360 degrees of sterilization, achieving sterilization affect three times as much as that of water surface bacterial lamps. It is designed by the principle that the uv of uv-c (253.7nm wavelength) can damage and kill the microorganism DNA. It is equipped with the high-purity quartz tubes, high-performance quartz low-voltage mercury UV bactericidal lamps and ballast especially for UV bactericidal lamps.
Characteristics of the immersion ultraviolet sterilizer:
1. High water-proof performance, compacted design and convenient for use:
2. Equipped with the high light transmittance quartz socket tubes:
3. The UV bacterial lamp is of high radiation efficiency and stable output power:
4. Equipped with the long service life low-voltage mercury ultraviolet lamps which can serve at least 9000 hours and guarantee the stable UV-C output within the service life:
5. Equipped with the ballasts specially designed for the ultraviolet sterilizer (replaceable). When the lamp does not work, alarm is sounded:
Applicable Range
The immersion UV sterilizer can effectively sterilize and purify water tanks and pools of various water bodies and liquid, effectively prevent the secondary pollution and maintain the cleanness of water, applicable for water supplied by different qualities, and industries demanding water supplied by time and section as electronics, pharmacy, food and cosmetics.
Technical Parameters:
Material: Stainless steel, carbon steel
Certificate: CE, ISO
Power supply: 220V, 50Hz
Lifespan of lamp: 9000 hours
Efficiency: 99%
Interface type: Thread or flange
Works: Automatic
Max pressure: 0.6Mpa
Working temperature: No more than 50 centigrade
Model |
UV lamp
length*diameter(mm) |
Thread |
Power
(watt) |
Current
(mA) |
Voltage
(V) |
ultraviolet intensity
(1mw/cm²) |
Flow rate
(GPM) |
YLCn-0.5 |
240*40 |
M34*2 |
6 |
160 |
40 |
15 |
0.5 |
YLCn-0.5 |
316*40 |
M34*2 |
8 |
150 |
55 |
21 |
0.5 |
YLCn-1 |
226*40 |
M34*2 |
10 |
180 |
35 |
25 |
1 |
YLCn-2 |
316*40 |
M34*2 |
14 |
175 |
46 |
28 |
2 |
YLCn-3 |
386*40 |
M34*2 |
17 |
170 |
60 |
35 |
3 |
YLCn-5 |
465*40 |
M34*2 |
21 |
160 |
89 |
60 |
5 |
YLCn-6 |
553*40 |
M34*2 |
25 |
250 |
50 |
70 |
6 |
YLCn-12 |
822*40 |
M34*2 |
38 |
290 |
56 |
100 |
12 |
YLCn-12 |
872*40 |
M34*2 |
40 |
370 |
58 |
130 |
12 |
UVC systems virtually eliminate microbiological contaminants without using potentially hazardous chemicals. Water enters through the bottom port of the ultraviolet generator cell and swirls around a low pressure mercury vapor lamp, which emits powerful ultraviolet light energy at 235.7nm wave length. Bacteria, viruses and other micro-organisms absorb the light energy which disrupts their DNA, and are destroyed safely inside a factory tested stainless steel cell. The treated water then exits through the top port of the cell and is ready for consumption.
What is the proper maintenance schedule for UV sterilizers?<o:p>
The quartz sleeve will need to be checked monthly and removed and cleaned with rubbing alcohol. Some larger UV sterilizers have wiper mechanism units installed for easier maintenance.<o:p>
For most units, the UV bulb will need to be replaced after 6 months of continuous use, however, this time may vary so be sure to follow the manufacturer's recommendations. When installing or changing a bulb, never look directly at the bulb when the unit is turned on. Doing so can result in permanent damage to your eyes. (The damage can occur without you feeling any discomfort.)<o:p>
Always disconnect the unit from the electricity when performing maintenance to protect against possible shock. When turned on, the bulb becomes especially hot when in the air and submerging it in water may cause it to break.<o:p>