3m3/H Ion Exchange Water Softener

Product Details
Customization: Available
Type: Conditioner
Usage: Environmental Protection
Still deciding? Get samples of US$ 1250/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • 3m3/H Ion Exchange Water Softener
  • 3m3/H Ion Exchange Water Softener
  • 3m3/H Ion Exchange Water Softener
  • 3m3/H Ion Exchange Water Softener
  • 3m3/H Ion Exchange Water Softener
  • 3m3/H Ion Exchange Water Softener
Find Similar Products

Basic Info.

Model NO.
YL-II-3
Motive Force
Electric power
Style
Vertical
Performance
Sophisticated Filters
Certification
ISO
Hardness of Raw Water
≤8mmol/L
Power Supply
220V/50Hz
Free Chlorine
≤0.3mg/L
Iron Content
<0.3mg/L
System Water Temperature
2-50ºC
Inlet Water Pressure
0.25~0.5MPa
Control Mode
Flow Rate/Time Based Control Type
Suspended Soild
<0.5mg/L
Resin
Strong Acidic Cation Exchange Resin
Working Ambient Temperature
5-50ºC
Transport Package
Plywood Case
Specification
350*1400mm
Trademark
YLD
Origin
Jiangsu, China
HS Code
8421219990

Product Description

3m3/h Ion Exchange Water Softener
 


3m3/H Ion Exchange Water Softener


Application scope of softener

Mainly used in industry and civil water softening preparation, such as Boiler feed water make-up water, air conditioning system make up water, heat exchanger, power plant, chemical, textile, printing and dyeing, bio-pharmaceutical, Electronic system and water pretreatment.


3m3/H Ion Exchange Water Softener

Type choice:


Softener equipment applies cation resin for softing raw water,its main target is to use cation resin to adsorp (main parts of ),encreasing the hardness of raw water.
1. Users can choose manual operation control system for saving cost.
2. If users using for 24 hours can accord to water using time choosing for rebirth
3. Uses can according to water quality requirement:first grade multi-media filter,which can remove mud,rust,colloid and suspension in water.Second grade activated carbon filter,which can remove color,olfactory,biochemistry organic in water and encrease the left oxygen value and pollution in water.Third grade equiped softener equipment.
4. Effluent water capacity achieves the water supply of national low-pressure bioler.
5. Time control- type;flow control- type.In working ,apply single-tank,double-tank and multi-tank etc. other varied combination method.When choosing,users can choose as their needs.In operation,it has not only automatic function,but also is manual operation.
Technoloty index and working
Water pressure:0.18-0.6Mpa 
Working temperature:1°c-55°c
Hardness of raw water: <8mmol/L 
Operation method:manual/automatic
Hardness of effluent water: ≤0.03mmol/L 
water flow: 0.3-100 m3/hour



Introduction 

Ion exchange units that replace calcium and magnesium ions from water are known as water softeners. They may also remove varying amounts of other inorganic pollutants such as metals, but they will not remove organic chemicals, pathogens, particles, or radon gas. Water softener units work most efficiently with particulate-free water.  
3m3/H Ion Exchange Water Softener




How does water softener work?(Principles of Ion Exchange to Soften Water )
Calcium and magnesium ions are atoms having a positive electrical charge, as do sodium and potassium ions. Ions of the same charge can be exchanged. In the ion exchange process, a granular substance (usually a resin) that is coated with sodium or potassium ions comes into contact with water containing calcium and magnesium ions. Two positively charged sodium or potassium ions are exchanged (released into the water) for every calcium or magnesium ion that is held by the resin. This "exchange or trade" happens because sodium or potassium are loosely held by the resin. In this way, calcium and magnesium ions responsible for hardness are removed from the water, held by the resin, and replaced by sodium or potassium ions in the water. This process makes water "soft." Eventually, a point is reached when very few sodium or potassium ions remain on the resin, thus no more calcium or magnesium ions can be removed from the incoming water. The resin at this point is said to be "exhausted" or "spent," and must be "recharged" or "regenerated."


3m3/H Ion Exchange Water Softener

The Control Valve and Regeneration
The control valve is the traffic cop in your water softener system. It determines when it is time to clean those plastic beads which are now coated with calcium and magnesium. Older style units use a timer, newer models use a computer controlled meter that determines when it is time based on actual water usage.



Specification

3m3/H Ion Exchange Water Softener


 









Contact information:
Official website:yldwater.en.made-in-china.com
Guarantee period:1 year





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier