Water Treatment Plant Hardness Removal Water Softening System

Product Details
Customization: Available
Water Hardness of Raw Water: <8mmol/L
Turbidity of Raw Water: <5ntu
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Water Treatment Plant Hardness Removal Water Softening System
Find Similar Products

Basic Info.

Model NO.
YL-II-10B
Water Output
<0.03mmol/L
Working Pressure
0.2-0.4MPa
Control for Regeneration
Flow Rate Based Control
Working Temperature
5 to 50 Centigrade
Free Chlorine
<0.5mg/L
Water Temperature
5-45 Centigrade
Iron Content
<0.3mg/L
Suspended Solid
<0.5mg/L
Transport Package
Plywood Case Into Container
Specification
refer to parameters sheet or to be customized
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
100 Units/Month

Product Description

ion-exchange  Water Softener 

Working configuration:singe-valve and dual-tank,one tank is working,the other tank is standby,alternative regeneration for continuous 24 hours working.
 
01. By means of Absorbing the calcium and magnesium ions in water with resin, since the hardness of water is mainly composed of calcium and magnesium, in general, we adopt cation exchange resin (softener), replace Ca2+, Mg2+ (main ingredients for scale) in water, as the increase of Ca2+ and Mg2+ in resin, removing performance on Ca2+, Mg2+ of resin will gradually reduce.
02. When the resin has absorbed a certain amount of calcium and magnesium ions, it must be regenerated, the regeneration process is that flush resin layer with the salt water in salt box, replace hardness ion out of the resin again, and discharged from the tank with waste liquid of regeneration, then resin resumed the function of softening and exchanging.
03. The principle of sodium ion exchange and softening treatment is to exchange cation in the raw water with resin, hardness constituents Ca2+and Mg2+ in water exchange Na+ in resin, thus absorb the Ca2+and Mg2+ to make the water to be softened.
2RNa + Ca2+ = R2Ca + 2Na+
2RNa + Mg2+ = R2Mg + 2Na+
After the water treated by sodium ion exchanger, the Ca+ and Mg+ were superseded by Na +.
Application scope of softener
Mainly used in industry and civil water softening preparation, such as Boiler feed water make-up water, air conditioning system make up water, heat exchanger, power plant, chemical, textile, printing and dyeing, bio-pharmaceutical, Electronic system and water pretreatment.
Type choice:
Softener equipment applies cation resin for softing raw water,its main target is to use cation resin to adsorp (main parts of ),encreasing the hardness of raw water.
1. Users can choose manual operation control system for saving cost.
2. If users using for 24 hours can accord to water using time choosing for rebirth
3. Uses can according to water quality requirement:first grade multi-media filter,which can remove mud,rust,colloid and suspension in water.Second grade activated carbon filter,which can remove color,olfactory,biochemistry organic in water and encrease the left oxygen value and pollution in water.Third grade equiped softener equipment.
4. Effluent water capacity achieves the water supply of national low-pressure bioler.
5. Time control- type;flow control- type.In working ,apply single-tank,double-tank and multi-tank etc. other varied combination method.When choosing,users can choose as their needs.In operation,it has not only automatic function,but also is manual operation.
Technoloty index and working
Water pressure:0.18-0.6Mpa 
Working temperature:1°c-55°c
Hardness of raw water: <8mmol/L 
Operation method:manual/automatic
Hardness of effluent water: ≤0.03mmol/L 
water flow: 0.3-100 m3/hour
 
Rebirth method:
Control method: time or flow
Working electric: 220V/50Hz
 
 Usage:
System automatic water softener widely used in steam bioler,heating bioler,exchanger,air conditioner, and other systems water softener,also used in hotel,restruant,office, and other life water treatment and food,drinking,wine,washing,textile,chemical,medicine and other industrial softener water treatment.

Water softener for hardness removing 
Model I : dual-tank and dual-valve, two tanks running simultaneously and regenerate respectively. 
   Model water output
(m³/hour)
Resin-tank
(diameter*Height)
Salt box
(Liter)
Resin
(kg)
connecting pipe(inch)
YLD-12FK 12 600mm*1850mm 350 400 1.5
YLD-20FK 20 750*1850 500 700 2
YLD-25FK 25 750*1850 500 700 2
YLD-36FK 36 900*2400 1000 1200 3
YLD-38FK 38 900*2400 1000 1200 3
YLD-42FK 42 1000*2400 1500 1400 3
YLD-45FK 45 1200*2400 2000 2000 3
YLD-60FK 60 1200*2400 2000 2000 3
YLD-100FK 100 1500*2400 2000 3000 3
 
 
Model II.:dual-tank and single valve,running mode :one tank is running,
the other one is stand-by.
   Model water output
(m³/hour)
Resin-tank
(diameter*Height)
Salt box
(Liter)
Resin
(kg)
connecting pipe(inch)
YLD-FK-200 0.5 200mm×1200mm 60 25 3/4
YLD-FK-250 1 250×1400 60 25 3/4
YLD-FK-300 2 300×1400 100 50 1
YLD-FK-350 3 350×1650 200 75 1
YLD-FK-400 4 400×1800 200  100 1
YLD-FK-600 6 600×1850 350  200 1.5
YLD-FK-750 10 750×2400 500  350 1.5
YLD-FK-900  16  900*2400  1000  600  2
YLD-FK-1000  20  1000*2400  1500  700  2
YLD-FK-1200  28  1200*2400  2000  1000  3
YLD-FK-1500  50  1500*2400  2000  1500  3
 
 
 
 
 
 
 
 
Model III. Single-tank and single-valve(time setting based or flow rate based) 
   Model water output
(m³/hour)
Resin-Tank
(diameter*Height)
Salt box
(Liter)
Resin
(kg)
connecting pipe(inch)
YLD-FK-0.5 0.5 200mm×1200mm 60 25 3/4
YLD-FK-1 1 250×1400 60 25 3/4
YLD-FK-2 2 300×1400 100 50 1
YLD-FK-3 3 350×1650 200 75 1
YLD-FK-4 4 400×1650 200  100 1
YLD-FK-5 5 500×1800 200  150 1
YLD-FK-6 6 600×1850 350  200 1.5
YLD-FK-10 10 750×1850 500  350 1.5
YLD-FK-16  16  900*2400  1000  600  2
YLD-FK-20  20  1000*2400  1500  700  2
YLD-FK-28  28  1200*2400  2000  1000  3
YLD-FK-50  50  1500*2400  2000  1500  3
 