UV Water Filter for Secondary Water Supply
Product Description
1. Kill 99% bacteria within 1 to 2 seconds.
2. Has broadest spectrum, can kill bacteria and virus thoroughly.
3. without secondary pollution
4. Environmentally friendly.
5. Low maintenance cost, easy to operate.
6. Occupying little space without noise
How Does UV Sterilisation Work?
UV sterilizers utilize germicidal ultraviolet lamps that produce short wave radiation lethal to bacteria, viruses and other microorganisms present in water. Ultraviolet water treatment purification is a unique and rapid method of water disinfection without the use of heat or chemicals. Through the years ultraviolet technology has become well established as a method of choice for effective and economical water disinfection.
What Contaminants Do UV Sterilizers Remove?
There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%.
CONVENTIONAL METHODS OF WATER TREATING |
| CHLORINE | OZONE | ULTRA VIOLET |
Capital cost | Lowest | High | Low |
Ease of installation | Good | Poor | Excellent |
Ease of Maintenance | Good | Poor | Excellent |
Cost of Maintenance | Medium | High | Lowest |
Operating Cost | Low | High | Low |
Frequency Of Maintenance | Frequent | Continuous | V. Infrequent |
Control System | Poor | Good | Excellent |
Virucidal Effect | Good | Poor | Good |
Toxic Chemical | Yes | Yes | No |
Residual Effect Problem with | Yes | Yes | No |
Hazards | High | Yes | Low to none |
Contact Time | 30 - 60 minutes | High | 1 - 5seconds |
Disinfection Performance | Leaves some pathogens | Kills all microbes | Kills all microbes |
Effect on Water | Organochlorine compounds, Taste & pH changes | Unknown | None |
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed. |
Technical parameters:
model | capacity | Power | inlet-outlet | reactor | panel | Anchor | G weight |
| m³/hour | watt | mm | L×W×H | cm | screw | Kg |
YLCn-005 | 0.3 | 16 | 1/2″ | 30×6×11 | without | without | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 47×6.3×11 | without | without | 10 |
YLCn-050 | 2 | 40 | 1″ | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 100×11×23 | | 69×4×Φ1 | 30 |
YLCn-200 | 8 | 120 | 1+1/2″ | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 100×15.9×32 | | 69×7×Φ1 | 40 |
YLC-050 | 2 | 40 | DN25/1″ | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 100×10.8×30 | | 60×4×Φ1 | 50 |
YLC-200 | 8 | 120 | DN40/11/2″ | 100×15.9×40 | | 60×7×Φ1 | 60 |
YLC-300 | 12 | 160 | DN50/2″ | 100×15.9×40 | | 60×7×Φ1 | 70 |
YLC-360 | 15 | 200 | DN65/21/2″ | 100×15.9×40 | | 60×7×Φ1 | 120 |
YLC-500 | 20 | 240 | DN65/21/2″ | 100×21.9×50 | | 60×11×Φ1.2 | 130 |
YLC-600 | 25 | 280 | DN80/3″ | 100×21.9×50 | | 60×11×Φ1.2 | 140 |
YLC-700 | 30 | 320 | DN100/4″ | 100×21.9×50 | | 60×11×Φ1.2 | 150 |
YLC-1000 | 40 | 360 | DN100/4″ | 100×21.9×50 | | 60×11×Φ1.2 | 160 |
YLC-1200 | 50 | 400 | DN125/5″ | 100×21.9×50 | | 60×11×Φ1.2 | 180 |
YLC-1500 | 60 | 420 | DN150/6″ | 170×27.3×57 | | 120×16×Φ1.4 | 210 |
YLC-2000 | 80 | 560 | DN150/6″ | 170×27.3×57 | | 120×16×Φ1.4 | 220 |
YLC-2500 | 100 | 700 | DN150/6″ | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 170×27.3×57 | | 120×16×Φ1.4 | 300 |
YLC-4000 | 150 | 1120 | DN200/8″ | 173×32.5×65 | | 120×20×Φ1.6 | 325 |
YLC-5000 | 200 | 1400 | DN200/8″ | 173×37.7×72 | | 120×22×Φ1.6 | 350 |
YLC-7000 | 300 | 2100 | DN250/10″ | 175×42.6×80 | | 120×24×Φ2.0 | 400 |
YLC-10K | 400 | 2520 | DN250/10″ | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 176×78×110 | | 120×32×Φ2.4 | 600 |
YLC-20K | 800 | 3920 | DN350/14″ | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | Designated | Designated | Designated | Designated |
Applications:
1. living water, drinking water, pure water and mineral water
2. swimming pool, landscape water, ciculating cooling water
3. food, cosmetic, medicine
4. sewage treatments
5. TOC reduction of electronic ultra-pure water
6. Aquarium
FAQ:
Is UV 100% effective?
UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses.
Does UV remove E. coli?
Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system.
How much does it cost to operate? UV systems are extremely economical to operate.
A typical household UV system operates on the same power requirements as a 40 watt light bulb!
Will UV change the taste or smell of my water?
UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection.
How do I know the system is working?
All UV systems come with "lamp-out" monitors which give an audible and visual signal in case of lamp failure. Sterilight GOLD systems incorporate true UV intensity monitors so an alarm will sound if the disinfection effectiveness falls below a safe level.
Why do I need Disinfection?
Disinfection is required on all water supplies that are not protected by a municipal water source. Due to the uncertainties that exist within some water systems, we can no longer rely on the fact that our water supplies "may be safe." By providing your own disinfection, you are taking the responsibility of ensuring the safety of the water supply for you and your family.