120m3/h 1200W Industrial Ultraviolet Water Sterilizer
Using Effect
⊙ Has processed after the ultraviolet ray decontamination system water body, its various virus, the bacterium except rate reach above 99%.
⊙ Has a drinking together the water used terminal to add with the ultraviolet ray disinfection, may achieve the direct tap water the standard.
⊙ To the cities sewage disinfection, the bacterium total quantity falls to 200 /100ml below, below backwoods coli 20 /100ml
Using conditions
1 Water temperature: 5 ºC ~ 50 ºC; Use ambient temperature: -5 ºC ~50 ºC; Periphery relative temperature: Is not bigger than 93%(temperature 25 ºC)
2 Voltages: Alternating current 220V±10V, 50Hz. (customized according to requirements).
3 Cultivations water used: After filters or other processing filters of the fresh water, the sea water.
4 Sewage: According to sterilizer request to enter 1cm the transmittance
(T 254): >= 40%; Other requests satisfy the country" Sewage To discharge Standard" in the GB8978-1996 two levels of standards.
5 Needs to process the water, like the water quality cannot achieve the above request, should first pass through suitable front to process, like the flocculation, the precipitation, filters and so on the method, by except dehydration in each kind of impurity.
Fields of application
Reclaimed water recycling
Devices for secondary water supply of the living community
Disinfection of the treated municipal sewer
Disinfection of water for aquiculture and processing
Disinfection of purified water for shellfish species
Disinfection of water in aquaria and water tanks
Disinfection of tap water, purified water and mineral water
Disinfection of water for the food and beverage industries_
Disinfection of water for such water recreational facilities as swimming poor, etc. Disinfection of drinking water for residential, office and restaurant buildings, etc. Disinfection of bacteria-free water for pharmacy, cosmetics and other such manufacturing industries
Disinfection of water for hospitals Water for military bases, ships and vessels and submarine vessels as well as field activities
Disinfection of water for agricultural irrigation
Disinfection of water for municipal landscapes
Disinfection of water for the water treatment system of central air conditioning in commercial buildings
Disinfection of cooling water for various large power stations
Disinfection of drinking water for commercial planes and large passenger planes Disinfection of water for large poultry and livestock farms
Disinfection of water for small domestic drinking machine
Greenhouse seedling culture Aquaculture
Water for municipal landscapes
Disinfection of water for hospitals
Food and beverage
Principle for UV sterilization
All forms of life known on the earth exist on the basis of DNA and RNA for reproduction and existence. DNA and RNA are both composed of 4 kinds of chemical substance units.
A--Adenine
T--Thymine
C--Cytosine
G--Guanine (the basic component for the nucleic acid)
In time of cell reproduction, the long chains inside DNA are opened when Unit A in each chain will look for and connect with Unit T. Each long chain can reproduce an identical chain to the chain freshly split, restore the complete DNA before splitting and serve as the foundation for the new-borne cells. However, the ultraviolet at a wave length of 240-270nm is able to break the capacity of DNA to produced protein and reproduction. Once the DNA and RNA of bacteria and viruses are damaged, their capacity to produce protein and reproduction are both lost. As the bacteria and viruses usually have a very short life cycle, those will soon perish that cannot reproduce.
The effective of UV sterilization is often expressed in killing ratio, e.g., 99.9%. Namely, 99.9% of the original bacteria have been killed and only 0.1% exists, or, 1/1 000 has survived. As 1000 is the 3 in 103 or in log, it is habitually to express the killing ratio with 310g. The killing ratio of ultraviolet depends on two factors: 1, ultraviolet intensity (I); and 2, irradiation time (T).
Advantages of Modern UV C Disinfection)
The UV C Disinfection Technology has been widely accepted by the world for its superior effect in disinfection on cell viruses and other Factors to be Considered Liquid chlorine disinfection Chlorine dioxide disinfection Ozone disinfection LW disinfection pathogenic agents. UVC water disinfection technology has the following obvious advantages.
High-efficiency sterilization
Sterilization of cell viruses with UV C is generally within one second. In comparison, the traditional UV and Cl and Ozone Methods takes 20 min to one hour to match the effect of UVC.
No secondary pollution
As the UV-c Technology can be controlled within the scope of killing the bacteria or viruses only and it is unnecessary to add any chemicals, it Operation complexity Simple to middle grade Simple to middle grade will not cause the secondary pollution to the water body and the surround environment. Meanwhile, it will not change any component of the water.
It makes continuous mass sterilization possible.
The modern UV-C disinfection equipment can work 24 hours a day and 365 days a year. Except for the general maintenance within the fixed time, the optimum operation condition is the 24-hour continuous operation.
Operation and maintenance is simple and easy and of low cost.
With the improvement of UV-C core technology, the UV-C disinfection technology is not only the means of the highest disinfection rate of all the disinfection methods but also the simplest and easiest in operation and maintenance and of the lowest cost, reaching RMB 0.004 Yuan/T of water. Therefore, cost performance ratio is the highest of all the disinfection technologies. It has the high efficiency advantage superior to other sterilization technologies but also is the lowest in cost and expenses for operation and maintenance.
Safe and Reliable Operation
In terms of the traditional sterilization technology, like the methods of using the chloride or ozone, the disinfectant itself is highly toxic, flammable and explosive. Application of these substances causes latent threat to the site operators, the surrounding environment and the nearby residents. The modern ultraviolet disinfection system, however, does not bear such potential risks.
Technical parameters:
Model |
Amount of
disinfectant |
Power
(W) |
Incoming and outcoming
water pipes
(Nominal/ British system) |
System pressure
resistance (Kg/cm²) |
UV light
fault Alarm |
Dimension
of the reactor
(cm)
L×W×H |
Dimension of
the control
cabinet
(cm) |
Anchor
screws |
Transport
weight(Kg) |
YLCn-005 |
0.3 |
16 |
1/2″ |
6 |
Has |
30×6×11 |
|
|
5 |
YLCn-008 |
1 |
25 |
1/2″ |
6 |
Has |
47×6.3×11 |
|
|
10 |
YLCn-050 |
2 |
40 |
1″ |
6 |
Has |
100×9×20 |
Φ8.9×25
(d×L) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4″ |
6 |
Has |
100×11×23 |
×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2″ |
6 |
Has |
100×15.9×30 |
Φ8.9×45
(d×L) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2″ |
6 |
Has |
100×15.9×32 |
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1″ |
6 |
Has |
100×8.9×30 |
25×30×12
(W×H×D) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/11/4″ |
6 |
Has |
100×10.8×30 |
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/11/2″ |
6 |
Has |
× |
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2″ |
6 |
Has |
100×15.9×40 |
×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/21/2″ |
6 |
Has |
100×15.9×40 |
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/21/2″ |
6 |
Has |
× |
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3″ |
6 |
Has |
100×21.9×50 |
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4″ |
6 |
Has |
100×21.9×50 |
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4″ |
6 |
Has |
100×21.9×50 |
×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5″ |
6 |
Has |
100×21.9×50 |
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
″ |
6 |
Has |
× |
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6″ |
6 |
Has |
170×27.3×57 |
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6″ |
6 |
Has |
170×27.3×57 |
60×128×30
× |
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6″ |
6 |
Has |
170×27.3×57 |
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8″ |
6 |
Has |
173×32.5×65 |
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8″ |
6 |
Has |
173×37.7×72 |
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
″ |
6 |
Has |
175×42.6×80 |
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10″ |
6 |
Has |
176×52.9×95 |
60×150×40
× |
120×22×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12″ |
6 |
Has |
176×78×110 |
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
″ |
6 |
Has |
Designated |
Designated |
Designated |
Designated |
YLC-25K |
1000 |
4760 |
DN350/14″ |
6 |
Has |
Designated |
Designated |
Designated |
Designated |
Notes:
1. Device Power: 220V/ 50HZ, service life of the UV light tube is ≥9000 hours.
2. This Table for Technical Parameters lists the units which can be used for disinfection of such pure water as: tap water, purified water, water for
aquaculture and livestock and poultry husbandry, water for food processing, supply of water of different qualities and water for medical
purposes, etc.
3. The sterilization efficiency depends on the transparency, impurities and temperature of the water and the sterilization efficiency is 99% or
designed for special purposes.
4. YLCn refers to the thread filling while YLC refers to the joint of flange adapter.
5.Various of. advanced online monitoring instrument and meters as well as remote monitoring system can be allocated for the specific demand
of users, for example: UV lamp monitoring system, UV intensity monitoring systems, water temperature detection system and disinfection time
accumulating system, etc.
Installation and method
1st, this equipment uses when should be vertical either straight lie the laying aside or twists on the support, meets the water pipe to be supposed the bottom to enter outdoes.
2nd, first opens the inlet valve gate slowly to enter the water, after and so on the hydraulic pressure is stable waits a bit one, two minutes, then installs the ultraviolet lamp tube the circular telegram to start to work, service condition observation acoustic optics alarm system.
3rd, this equipment uses when should the continuous observation ultraviolet lamp tube color whether is weaken, changes color and extinguishes above, if has the situation namely to have to exchange the new lamp tube; In the normal service condition, the lamp tube service life approximately is 9,000 hours, at the appointed time should replace the new lamp tube, guarantees the sterilization effect.