Working principle
254nm UV light water disinfecion sterilizers for fish ponds use the ultraviolet technology to remove the bacterials and organisms which are harmful to fishes in water.UV light disinfection is an effective method in destroying micro-organisms in a water stream and an endorsed technology currently being used by a wide range of manufacturers and industries. UV radiation has three wavelength zones: UV-A,UV-B, and UV-C, and it is this last region, the short wave UV-C, that has germicidal properties for disinfection. Ultraviolet systems use low-pressure mercury lamps that emit UV light in the range of 254nm that attacks the microorganism and stops the microorganism's ability to function and reproduce.
A UV sterilizer is used to control infections by stopping the spread of microorganisms from one fish/coral/invertebrate to another through the water. It is also used in pond applications to control free-floating algae. When operated correctly, free-floating microorganisms will be killed by the UV light. Note that the organisms must be in the water that flows to the UV sterilizer. The UV light has no residual effect and will not kill organisms attached to fish or rocks .
Water Quality (Feed in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron |
≤0.3ppm(0.3mg/L) |
Hardness |
≤7gpg(120mg/L) |
Turbidity |
≤1NTU |
Manganese |
≤0.05ppm(0.05mg/L) |
Tannins |
≤0.1ppm(0.3mg/L) |
UV Transmittance |
≥750‰ |
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter (μW-s/cm2) Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2) |
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies |
850-980‰ |
De-ionized or Reverse Osmosis water |
950-980‰ |
Surface waters(lakes, rivers, etc) |
700-900‰ |
Ground water(wells) |
900-950‰ |
Other liquids |
10-990‰ |
Advantages
Effective: Virtually all microorganisms are susceptible to UV disinfection
Automatic: Continuous or intermittent disinfection without special attention
Fast: Water is ready for consumption as soon as it leaves the cell
Easy: Simple installation and maintenance. Minimum space requirements
Safe: No danger or way of overdosing, no addition of hazardous chemicals
Economical: Hundreds of gallons of water can be purified for a few cents per day
No Chemicals: No chlorine taste or corrosion problems
Technical Parameter
Model |
Water Flow | Power | Inlet/Outlet Diameter |
Reactor Diameter(L*W*H) |
Control Cabinet(L*W*H) |
|
(m3/h) | W | mm | in | mm | mm | |
YLCn-005 | 0.3 | 16 | 20 | 1/2" | 350*63*110 | N/A |
YLCn-008 | 1 | 25 | 20 | 1/2" | 470*63*110 | N/A |
YLCn-050 | 2 | 40 | 25 | 1" | 930*76*130 | N/A |
YLCn-150 | 6 | 80 | 32 | 1+1/4" | 930*108*240 | 250*140*300 |
YLCn-200 | 8 | 120 | 40 | 1+1/2" | 930*133*270 | 250*140*300 |
YLCn-300 | 12 | 160 | 50 | 2" | 930*159*290 | 300*150*400 |
YLC-360 | 15 | 200 | 65 | 2+1/2" | 930*159*370 | 300*150*400 |
YLC-500 | 20 | 240 | 65 | 2+1/2" | 930*159*370 | 300*150*400 |
YLC-600 | 25 | 280 | 80 | 3" | 930*159*370 | 300*150*400 |
YLC-700 | 30 | 320 | 100 | 4" | 930*159*370 | 300*150*400 |
YLC-1000 | 40 | 360 | 100 | 4" | 930*159*370 | 350*200*450 |
YLC-1200 | 50 | 400 | 125 | 5" | 930*219*450 | 350*200*450 |
YLC-1500 | 60 | 420 | 150 | 6" | 1630*219*450 | 400*200*500 |
YLC-2000 | 80 | 560 | 150 | 6" | 1630*219*450 | 400*200*500 |
YLC-2500 | 100 | 700 | 150 | 6" | 1630*219*450 | 400*200*500 |
YLC-3000 | 125 | 840 | 150 | 6" | 1630*219*450 | 500*200*600 |
YLC-4000 | 150 | 1120 | 200 | 8" | 1630*273*530 | 500*200*600 |
YLC-5000 | 200 | 1400 | 200 | 8" | 1630*273*530 | 500*200*600 |
YLC-7000 | 300 | 2100 | 250 | 10" | 1630*325*580 | 500*350*1000 |
YLC-10K | 400 | 2520 | 250 | 10" | 1630*325*580 | 500*350*1000 |
YLC-15K | 600 | 3080 | 300 | 12" | 1630*377*640 | 600*350*1200 |
Application
Ultraviolet water purification systems are used in many applications that includes home/residential(both well water and municipal water supplies), commercial, and industrial. Here is a list of several applications where the power of UV water sterilizers are commonly used to treat and protect the water supply for contaminates such as bacteria and viruses. UV systems applications include private wells, campgrounds, hotels, bottlers, aquaculture, hospitals, food, cottages, restaurants, breweries, water systems, laboratories, marine, pharmaceutical, dairies and many other applications.
To Customers
1.What is the water flow of your water system?
2.What is your raw water to be disinfected?
3.Do you need the accessories like flow switch,UV intensity detector,timer,etc?
4.Do you also require other kinds of filters for prefiltration used in your water system?