• Ion Exchange Resin Soften Type Water Softener
  • Ion Exchange Resin Soften Type Water Softener
  • Ion Exchange Resin Soften Type Water Softener
  • Ion Exchange Resin Soften Type Water Softener
  • Ion Exchange Resin Soften Type Water Softener
  • Ion Exchange Resin Soften Type Water Softener

Ion Exchange Resin Soften Type Water Softener

Water Hardness of Raw Water: <8mmol/L
Turbidity of Raw Water: <5ntu
Water Output: <0.03mmol/L
Working Pressure: 0.2-0.4MPa
Control for Regeneration: Flow Rate Based Control
Working Temperature: 5 to 50 Centigrade
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YL-I-6
Free Chlorine
<0.5mg/L
Water Temperature
5-45 Centigrade
Iron Content
<0.3mg/L
Suspended Solid
<0.5mg/L
Transport Package
Plywood Case Into Container
Specification
refer to parameters sheet or to be customized
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
100 Units/Month

Product Description

Ion Exchange Resin Soften Type Water Softener

How to Soften Hard Water
Hard water is high in minerals, usually calcium and magnesium. These minerals leave behind deposits that can clog drains, stain glass and tile, prevent soap from sussing, and leave a residue on hair and skin. Studies have not found any health risks or medical reasons for softening water, but it is an inconvenience nevertheless. There are several ways to soften hard water. See Step 1 and beyond to find the right method for you.
 

Determine if you're in a region that has hard water.
Although hard water exists in water sources in all US states, the highest concentration of hard water supplies in the United States include areas of Arizona, California, Kansas, New Mexico and Texas.
   If you use a public water supply, information about your level of water hardness is available from your local town hall water department.
   This information may also be available from your local town hall if you have private well. Based on your location, your city government may be able to tell you the primary source of water supplies for the area and give you some test results, including water softness levels.
  Bring a water sample to a local water testing lab to test your water hardness or use a commercially sold water hardness test kit if you have a private well and suspect your water is hard.
 
Watch the amount of foaming that occurs when you use cleaning products like toothpaste, dish soap, laundry detergent and other household cleaners. If you have to add a lot of soap to the water to work up suds, your water is probably hard.
 

Unit Selection
The selection of a water softening unit depends on the hardness of the raw water and the amount of water to be softened. There are manual, automatic, semiautomatic, and fully automatic units that differ in the degree of resin regeneration automation. First, the number of fixtures in the home that will require softened water must be determined. Then, all the fixtures' flow rates need to be added up. Note that conventional faucets use 3-5 gallons per minute (gpm) and conventional showers use 5-10 gpm. (Newer, water-saving fixtures may use only half these amounts.)
Working configuration:singe-valve and dual-tank,one tank is working,the other tank is standby,alternative regeneration for continuous 24 hours working.
 
01. By means of Absorbing the calcium and magnesium ions in water with resin, since the hardness of water is mainly composed of calcium and magnesium, in general, we adopt cation exchange resin (softener), replace Ca2+, Mg2+ (main ingredients for scale) in water, as the increase of Ca2+ and Mg2+ in resin, removing performance on Ca2+, Mg2+ of resin will gradually reduce.
02. When the resin has absorbed a certain amount of calcium and magnesium ions, it must be regenerated, the regeneration process is that flush resin layer with the salt water in salt box, replace hardness ion out of the resin again, and discharged from the tank with waste liquid of regeneration, then resin resumed the function of softening and exchanging.
03. The principle of sodium ion exchange and softening treatment is to exchange cation in the raw water with resin, hardness constituents Ca2+and Mg2+ in water exchange Na+ in resin, thus absorb the Ca2+and Mg2+ to make the water to be softened.
2RNa + Ca2+ = R2Ca + 2Na+
2RNa + Mg2+ = R2Mg + 2Na+
After the water treated by sodium ion exchanger, the Ca+ and Mg+ were superseded by Na +.
Application scope of softener
Mainly used in industry and civil water softening preparation, such as Boiler feed water make-up water, air conditioning system make up water, heat exchanger, power plant, chemical, textile, printing and dyeing, bio-pharmaceutical, Electronic system and water pretreatment.

Operation and Maintenance
Maintenance of water softeners is largely confined to restocking the salt supply for the brine solution. Semiautomatic models require either a manual start of the regeneration cycle or regular service for a fee.
The resin should never wear out. If resins are not regenerated on a regular basis, at the proper intervals, they may become contaminated with slime or impurities and require replacement. Resins can also become clogged with tiny particles of iron if the raw water contains that mineral. Back-washing, that is, reversing the normal flow of water through the treatment unit, may be required to remove the iron. Alternately, special additives may be added to the brine to help minimize this condition.

Type choice:
Softener equipment applies cation resin for softing raw water,its main target is to use cation resin to adsorp (main parts of ),encreasing the hardness of raw water.
1. Users can choose manual operation control system for saving cost.
2. If users using for 24 hours can accord to water using time choosing for rebirth
3. Uses can according to water quality requirement:first grade multi-media filter,which can remove mud,rust,colloid and suspension in water.Second grade activated carbon filter,which can remove color,olfactory,biochemistry organic in water and encrease the left oxygen value and pollution in water.Third grade equiped softener equipment.
4. Effluent water capacity achieves the water supply of national low-pressure bioler.
5. Time control- type;flow control- type.In working ,apply single-tank,double-tank and multi-tank etc. other varied combination method.When choosing,users can choose as their needs.In operation,it has not only automatic function,but also is manual operation.

Technoloty index and working
Water pressure:0.18-0.6Mpa 
Working temperature:1°c-55°c
Hardness of raw water: <8mmol/L 
Operation method:manual/automatic
Hardness of effluent water: ≤0.03mmol/L 
water flow: 0.3-100 m3/hour
 
Rebirth method:
Control method: time or flow
Working electric: 220V/50Hz,optional
 
Water softener for hardness removing 

Model I : dual-tank and dual-valve, two tanks running simultaneously and regenerate respectively. 
   Model water output
(m³/hour)
Resin-tank<mm>
(diameter*Height)
Brine-tank(Liter) Resin
(kg)
connecting pipe(inch)
YL-II-0.5A 0.5 200×1200 60 40 3/4
YL-II-1A 1 250×1400 60 80 3/4
YL-II-2A 2 300×1400 100 120 1
YL-II-3A 3 350×1650 200 160 1
YL-II-4A 4 400×1800 200 240 1
YL-II-5A 5 500×1800 200 360 1
YL-II-6A 6 600×1850 350 480 1.5
YL-II-10A 10 750×1850 500 720 1.5
YL-II-18A 14-18 900×1850 500 720 1.5
YL-II-25A 20--25 750*1850 500 720 2
YL-II-36A 30--36 900*1900 800 1040 3
YL-II-50A 45--50 1200*2400 1000 1440 3
YL-II-70A 60--70 1200*2400 1500 2000 3
YL-II-100A 80--100 1500*2500 2000 3200 3

Model II.:dual-tank and single valve,running mode :one tank is running,the other one is stand-by.
   Model water output Resin-tank<mm> Brine tank
(Liter)
Resin
(kg)
connecting pipe(inch)
m³/hour  (diameter*Height)
YL-II-1B 1 250×1400 60 80 3/4
YL-II-2B 2 300×1400 100 120 1
YL-II-3B 3 350×1400 100 160 1
YL-II-4B 4 400×1650 200 240 1
YL-II-5B 5 500×1750 300 360 1
YL-II-6B 6 600×1850 350 480 1.5
YL-II-10B 8--10 750×1900 500 720 1.5
YL-II-18B 12--18  900*2400 800 1040  2
YL-II-25B 20--25  1000*2200 1000 1440  2
YL-II-35B 30--35  1200*2400  1500 2000  3
YL-II-50B  40--50  1500*2400 2000 3200  3
 
Model III. Single-tank and single-valve(time setting based or flow rate based) 
 
   Model water output
(m³/hour)
Resin-Tank<mm>
(diameter*Height)
Brine tank
(Liter)
Resin
(kg)
connecting pipe(inch)
YL-I-0.5 0.5 200×1200 60 20 3/4
YL-I-1 1 250×1400 60 40 3/4
YL-I-2 2 300×1400 100 60 1
YL-I-3 3 350×1650 200 80 1
YL-I-4 4 400×1650 200 120 1
YL-I-5 5 500×1800 200 180 1
YL-I-6 6 600×1850 350 240 1.5
YL-I-10 10 750×1850 500 360 1.5
YL-I-16  16  900*2200  1000 520  2
YL-I-20  20  1000*2200  1500 720  2
YL-I-28  28  1200*2400  2000  1000  3
YL-I-50  50  1500*2400  2000  1600  3

Operation and Maintenance
Maintenance of water softeners is largely confined to restocking the salt supply for the brine solution. Semiautomatic models require either a manual start of the regeneration cycle or regular service for a fee.
The resin should never wear out. If resins are not regenerated on a regular basis, at the proper intervals, they may become contaminated with slime or impurities and require replacement. Resins can also become clogged with tiny particles of iron if the raw water contains that mineral. Back-washing, that is, reversing the normal flow of water through the treatment unit, may be required to remove the iron. Alternately, special additives may be added to the brine to help minimize this condition.