100GPM Stainless UV Sterilizers with Manual Cleaning System
Advantages:
UV light will kill any DNA based micro organism when give enough UV dosage.
UV break micro organism's DNA in a cumulative basis.
Continuous disinfection in cooling water. If micro organism is not effectively deactivated on the first disinfection cycle and in the next cycle it get UV treated.
For 90% kill algae 30000 μWs/cm2 is required for one cycle .
UV spectrum between 185-400nm has a strong germicidal effect, with peak effectiveness at 265nm.
UV works instantaneously against all water-borne microorganisms, including bacteria, viruses, molds, spores and protozoa - including those resistant to chlorine.
UV systems are also very easy to use and can be effectively monitored and integrated with online process control systems.
UV disinfection systems are very compact, modular and easy to
install into existing water treatment systems.
UV does not cause the formation of chemical disinfection by-
products, many of which can have undesired effects of their own.
UV sterilizer is eco-friendly and cost effective.
UV Disinfection Systems Application
1. Sterilization of domestic water, secondary water supply, direct drinking water, purified water and mineral water plant;
2. Sterilization of swimming pools, landscape water and circulating cooling water;
3. Sterilization of industrial water such as in food, cosmetic and pharmaceutical industry, etc.;
4. Sterilization before sewage discharge;
5. Sterilization of aquatic products and aquatic breeding industry;
Principle of Operation
Ultraviolet disinfection systems typically utilize thin cylindrical bulbs capable of generating narrow band wavelength UV light in the 254 nm range, placed in close proximity to high-purity glass tubes through which the water flows. The unit must be sized to provide adequate dosage at the specified flowrate. The water to be treated must be sufficiently free of turbidity (sediment), iron, manganese and any colorant that could affect transmission of the 254 nm UV light. Manufacturers' specifications should be consulted.
Stainless Steel Germicidal Ultra Violet Light Systems Offer a Natural Approach to Purifying Water Without Toxic Chemicals
Heavy duty, high pressure leak resistant units makes these lights perfect on the budget for a high quality Stainless Steel unit.
Highly polished stainless steel interior They are polished to a high luster/shine inside the reactor chamber wall for improved reflection of the UV light thus allowing for more killing power.
Thermically-sensitive electronic ballast further protects our new UVC lamp, by automatically shutting down when the unit becomes too hot, preventing damage to both the lamp and the unit (Restarts automatically when it cools down)
Technical parameters:
model |
Processing capacity (Ton/Hour) |
power (W) |
inlet and outlet
(inch) |
working pressure (Kg/cm 2 ) |
malfunction alert for UV lamp |
reactor dimension (cm) L×W×H |
dimension of panel(cm) |
anchor bolt (cm) |
overall weight (Kg) |
YLCn-005 |
0.3 |
16 |
1/2" |
6 |
matched |
30×6×11 |
|
|
5 |
YLCn-008 |
1 |
25 |
1/2" |
6 |
matched |
47×6.3×11 |
|
|
10 |
YLCn-050 |
2 |
40 |
1" |
6 |
matched |
100×9×20 |
Φ8.9×25
(diameter×length) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4" |
6 |
matched |
100×11×23 |
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2" |
6 |
matched |
100×15.9×30 |
Φ8.9×45
(diameter×length) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2" |
6 |
matched |
100×15.9×32 |
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1" |
6 |
matched |
100×8.9×30 |
25×30×12
(L×H×w) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/1 1/4 " |
6 |
matched |
100×10.8×30 |
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/1 1/2 " |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2" |
6 |
matched |
100×15.9×40 |
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/2 1/2" |
6 |
matched |
100×15.9×40 |
50×78×25
(L×H×W) |
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/2 1/2" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5" |
6 |
matched |
100×21.9×50 |
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6" |
6 |
matched |
170×27.3×57 |
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6" |
6 |
matched |
170×27.3×57 |
60×128×30
(W×H×T)
|
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6" |
6 |
matched |
173×27.3×57 |
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8" |
6 |
matched |
173×32.5×65 |
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8" |
6 |
matched |
173×37.7×72 |
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10" |
6 |
matched |
175×42.6×80 |
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10" |
6 |
matched |
176×52.9×95 |
60×150×40
(W×H×T) |
120×28×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12" |
6 |
matched |
176×78×110 |
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
confirmed |
YLC-25K |
1000 |
4760 |
DN350/14" |
6 |
matched |
confirmed |
confirmed |
confirmed |
Q. Does the water have to sit in the UV sterilizer to be disinfected?
A. No. If the system is sized correctly, the water is disinfected as it flows through.
Q. What if the water flows faster than is allowed through the system?
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded.
Q. How long does the lamp last?
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water.
Q. Are these systems bigger energy users?
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
Q. My water is sometimes cloudy. Is that a problem?
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated.