Cation Ion Exchange Water Softener Equipment Hard Water Treatment
Water Softener is a process of removing Calcium and Magnesium ions from water. Calcium and Magnesium are the hardness forming component of water. When hard water is passed through resin in Sodium form, Ca and Mg ions are exchanged for equivalent Na ions. The water which now contains only Sodium ions is called soft water. The soft water is then used as a feed water to low and medium pressure boiler, RO systems and also for Laundries and other application.
Specification :
§ Material of construction MS/FRP/MSRL/SS.
§ Designed as per ASME.
§ Well designed distribution system.
§ Well designed collection system.
§ High end water quality.
§ Suited regeneration time for various application.
§ High replacement of calcium and magnesium.
Application
§ Industrial Process Water.
§ Hospitals & Laundries.
§ Automobiles industries.
§ Domestic application.
§ Pre treatment of water.
§ Boilers and Cooling towers.
What do water softeners do?
Industrial water softeners are specific ion exchangers that are designed to remove ions which are positively charged.
Softeners mainly remove calcium (Ca2+) and magnesium (Mg2+) ions. Calcium and magnesium are often referred to as "hardness minerals". Softeners are sometimes even applied to remove iron.
The softening devices are able to remove up to five milligrams per liter (5 mg/L) of dissolved iron and can operate automatic, semi-automatic, or manual. Each type is rated on the amount of hardness it can remove before regeneration is necessary. Commercial water softeners collect hardness minerals within its conditioning tank and from time to time flushes them away to drain.
When an ion exchanger is applied for water softening, it will replace the calcium and magnesium ions in the water with other ions, for instance sodium or potassium. The exchanger ions are added to the ion exchanger reservoir as sodium and potassium salts (NaCl and KCl).
Technical parameters:
Category |
Model |
Recommended
water yield
(M³/h) |
Tank size
Diameter *Height(mm) |
Salt box
(L) |
Amount of resin(KG) |
Dual-valve and
dual-tank (simultaneous
operation and respective
regeneration) |
YL-II-36 |
24-36 |
900×1900 |
800 |
1040 |
YL-II-50 |
36-50 |
1000×2200 |
1000 |
1440 |
YL-II-70 |
50-70 |
1200×2400 |
1500 |
2000 |
YL-II-100 |
70-100 |
1500×2500 |
2000 |
3200 |
Dual-valve and
dual-tank(One for
use and the other for standby) |
YL-II-1 |
1 |
250×1400 |
60 |
80 |
YL-II-2 |
2 |
300×1400 |
100 |
120 |
YL-II-3 |
3 |
350×1400 |
100 |
160 |
YL-II-4 |
4 |
400×1650 |
200 |
240 |
YL-II-5 |
5 |
500×1750 |
300 |
360 |
YL-II-6 |
6 |
600×1900 |
350 |
480 |
YL-II-10 |
8-10 |
750×1900 |
500 |
720 |
YL-II-18 |
12-18 |
900×1900 |
800 |
1040 |
YL-II-25 |
18-25 |
1000×2200 |
1000 |
1440 |
YL-II-35 |
25-35 |
1200×2400 |
1500 |
2000 |
YL-II-50 |
35-50 |
1500×2500 |
2000 |
3200 |