Industrial Circulating Water Manual Control Bypass Sand Filter

Product Details
Customization: Available
Type: Sand
Usage: Environmental Protection, Chemical Industry, Water Treatment
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Industrial Circulating Water Manual Control Bypass Sand Filter
  • Industrial Circulating Water Manual Control Bypass Sand Filter
  • Industrial Circulating Water Manual Control Bypass Sand Filter
  • Industrial Circulating Water Manual Control Bypass Sand Filter
  • Industrial Circulating Water Manual Control Bypass Sand Filter
  • Industrial Circulating Water Manual Control Bypass Sand Filter
Find Similar Products

Basic Info.

Model NO.
YL-SF-1000
Motive Force
Pressure
Style
Vertical
Performance
Efficient Filtration
Certification
CE
Material for Shell Piping
Stainless Steel or PVC
Input Power
2~20kw
Power Supply
AC380V, 35A, 50Hz
Working Temperature
5-40centigrade
Working Filtration Rate
25~35m/S
Working Pressure
0.6~1.6MPa
Country
Russia
Water Distributor
Pagoda, Mushroom
Flow Rate
30m3/H
Inlet and Outlet
Dn50/2inch
Transport Package
Plywood Case in Container
Specification
CE, SGS
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
500sets/Year

Product Description

Industrial Circulating Water Manual Control Bypass Sand Filter

The size of each filter, the number of filters required, and the type of filter media used depend upon:

· How small a solid needs to be removed,
· How dirty the water is,
· How the water will be used once it is filtered,
· And the source of backwash water needed to clean the filters.

Size of Solids to be Removed: The smaller the solid to be removed, the slower the water must pass through the media and the finer the granule of media must be. Very often the end user doesn't know how small a solid must be removed. In those situations, how the filtered water will be used will determine how small a solid should be removed.

Concentration of Suspended Solids: The higher the concentration of suspended solids, the larger the diameter of the filter needs to be. All filters have a maximum concentration of suspended solids that can be managed without compromising filter performance.

Source of Backwash Water: Backwash water is used to clean the filters and flush out the suspended solids that have been trapped in the media bed. Water for backwashing can come either from the filters themselves or from an external source of clean water (such as a domestic water line or a storage tank).
If backwash water comes from the filter system, there must be more than one filter in the system. Filters are backwashed one-at-a-time. During the backwash cycle, a portion of filtered water exiting the other filter(s) in the system is used to clean the dirty filter. During these periods (which typically last for several minutes per filter), the amount of filtered effluent flowing downstream of the filter is reduced by the amount of water required for backwashing.

In cases where this temporary reduction in flow is acceptable, there will be two or more filters in the system.

If no decrease in the flow of filtered water can be accepted, then water for backwashing is supplied from an external source or the pump supplying water to the filters must be able to increase its output when backwashing is required.

Units are skid-mounted, and factory assembled, wired and tested. They are delivered ready for installation. Piping, valves, pressure gauges, filter media and accessories are included with the filter system.

Design Features of Sand and Multi-media Filters: Solar power, media air scour, and rinse cycle are available as options. Filter capacities are from 5 GPM to 14 MGD. Chemical injection packages, settling tanks, clarifiers, and disinfection units are also available.

O 8 in. To 12 ft. Diameter vessels
O Automatic or manual operation
O All steel construction (mild steel, 304 and 316 stainless steel)
O Stainless steel vessel internals
O ASME code or non-code vessels
O Hydraulic, pneumatic or electric valves
O High pressure and temperature options
O Class 1, Div. 1 or 2 preparation

Specification:
model Filter diameter Height inlet-outlet Filtration area capacity
mm mm mm m³/hour
YL-SF-500 500 816 40 0.2 6~10
YL-SF-600 600 874 40 0.28 8~14
YL-SF-700 700 900 40 0.38 12~19
YL-SF-800 800 960 DN50 0.50 15-25
YL-SF-1000 1000 1200 DN50 0.79 23-39
YL-SF-1200 1200 1400 DN80 1.13 33-55
YL-SF-1400 1400 1600 DN100 1.54 45-75
YL-SF-1600 1600 1800 DN100 2.01 60-100
YL-SF-1800 1800 1950 DN150 2.54 75-125
YL-SF-2000 2000 2150 DN150 3.14 95-155
YL-SF-2200 2200 2250 DN150 3.80 115-190
YL-SF-2400 2400 2100 DN150 4.52 130-210
YL-SF-2600 2600 2400 DN150 5.30 145-225
YL-SF-2800 2800 2500 DN200 6.15 155-240
YL-SF-3000 3000 2600 DN200 7.00 170-255
YL-SF-3200 3200 2800 DN250 8.15 270-320
 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier