40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying

Product Details
Customization: Available
Theory: UV Light Sterilization
Type: Lightwave Disinfection
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
  • 40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
Find Similar Products

Basic Info.

Model NO.
YLC-1000A
Certification
CE
Electric Tension
220V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
UV Light
UV-C 254nm Wavelength
Tube
Quartz Tube
Water Inlet Hardness
Less Than 120mg/Liter
Water Inlet Turbidity
Less Than 1 Ntu
Water Inlet Iron Content
Less Than 0.3 Mg/Liter
Water Inlet Manganese Content
Less Than 0.05 Mg/Liter
Cleaning Model
Hand-Cleaning, Rod Cleaning, Automatic Motor
Lifespan of UV Lamp
9000 to 12000 Hours
Control System
Control Box, PLC, Remote Control, etc
Water Output
1 to 500 Cubic Meter Per Hour
Transport Package
Plywood Case Into Container
Specification
to be customized
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
150 Units Per Month

Product Description


UV Sterilizers


What does a UV sterilizer do? <o:p>
A UV sterilizer is used to control infections by stopping the spread of microorganisms from one fish/coral/invertebrate to another through the water. It is also used in pond applications to control free-floating algae. When operated correctly, free-floating microorganisms will be killed by the UV light. Note that the organisms must be in the water that flows to the UV sterilizer. The UV light has no residual effect and will not kill organisms attached to fish (e.g., adult stage of inch) or rocks (e.g., algae).
40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying

How do UV sterilizers work? 
The UV sterilizer utilizes a germicidal fluorescent lamp that produces light at a wavelength of approximately 254 anemometers (2537 Angstroms). The water with the bacteria/algae passes over the bulb (or around the bulb if a quartz sleeve is used) and is irradiated with this wavelength. As the light penetrates the bacteria/algae, it mutates the DNA (genetic material), preventing growth/multiplication of the organism.
40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying

Application
1.Food processing industry, including juices, milk, drinks, beer, practical oil  and canned food.
2.Electronic industry.
3.Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4.Households building, residential, office buildings, hotels, restaurants, water factories.
5.Purification and disinfection of shellfish, fish cleaning and disinfection
6.Military camp, field water supply system
7.Urban wastewater disinfection.
8.Swimming pool, other recreational water disinfection 
9.Thermal power, nuclear power plant  industrial, central air conditioning system cooling water.
10.Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11.Sea water, fresh water breeding, aquaculture  water
12.Agricultural water disinfection
UV specification

 
40 M3/Hr Automatic Motor Cleaning UV Sterilizer for Water Purifying
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
 
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
 
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
 
                 DOSAGE is the product of intensity & time
dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
                              (μW-s/cm2)
               Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2)

Water Quality (in)
 
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
 
 
 
Maximum Concentration Levels (Very Important)
 

Iron

≤0.3ppm(0.3mg/L)

Hardness

≤7gpg(120mg/L)

Turbidity

≤1NTU

Manganese

≤0.05ppm(0.05mg/L)

Tannins

≤0.1ppm(0.3mg/L)

UV Transmittance

≥750‰

 
 
 
 
 
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
 
UV wavelength (nm)
 
 
 

                 DOSAGE is the product of intensity & time
dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
                              (μW-s/cm2)
               Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2)

 
 
 
As a general guideline, the following are some typical UV transmission rates (UVT)
 

City water supplies

850-980‰

De-ionized or Reverse Osmosis water

950-980‰

Surface waters(lakes, rivers, etc)

700-900‰

Ground water(wells)

900-950‰

Other liquids

10-990‰

 Parameters sheet
model capacity Power inlet-outlet reactor panel Anchor G weight
m³/hour watt mm L×W×H cm screw Kg
YLCn-005 0.3 16 1/2″ 30×6×11 without without 5
YLCn-008 1 25 1/2″ 47×6.3×11 without without 10
YLCn-050 2 40 1″ 100×9×20 Φ8.9×25
(d×L)
69×4×Φ1 25
YLCn-150 6 80 1+1/4″ 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2″ 100×15.9×30 Φ8.9×45
(d×L)
69×7×Φ1 35
YLCn-300 12 160 2″ 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1″ 100×8.9×30 25×30×12
(W×H×D)
60×4×Φ1 45
YLC-150 6 80 DN32/11/4″ 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/11/2″ 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2″ 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/21/2″ 100×15.9×40 60×7×Φ1 120
YLC-500 20 240 DN65/21/2″ 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3″ 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4″ 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4″ 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5″ 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6″ 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6″ 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6″ 170×27.3×57 60×128×30
(W×H×D)
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6″ 170×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8″ 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8″ 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10″ 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10″ 176×52.9×95 60×150×40
(W×H×D)
120×22×Φ2.2 475
YLC-15K 600 3080 DN300/12″ 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14″ Designated Designated Designated Designated
YLC-25K 1000 4760 DN350/14″ Designated Designated Designated Designated
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier