• Killing 99% of Germs and Viruses UV Water Sterilizer

Killing 99% of Germs and Viruses UV Water Sterilizer

Theory: UV Light Sterilization
Type: Lightwave Disinfection
Certification: CE
Electric Tension: 220V
LCD Display: With LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLC-2000
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
UV Light
UV-C 254nm Wavelength
Tube
Quartz Tube
Water Inlet Hardness
Less Than 120mg/Liter
Water Inlet Turbidity
Less Than 1 Ntu
Water Inlet Iron Content
Less Than 0.3 Mg/Liter
Water Inlet Manganese Content
Less Than 0.05 Mg/Liter
Cleaning Model
Hand-Cleaning, Rod Cleaning, Automatic Motor
Lifespan of UV Lamp
9000 to 12000 Hours
Control System
Control Box, PLC, Remote Control, etc
Water Output
1 to 500 Cubic Meter Per Hour
Transport Package
Plywood Case Into Container
Specification
refer to parameters sheet or to be customized
Trademark
YLD
Origin
Jiangyin, China
HS Code
842121999
Production Capacity
150 Units Per Month

Product Description


What is an Ultraviolet (UV) Pool Sanitizer?<o:p>
Ultraviolet (UV) pool sanitizers utilize a cutting-edge, non-chemical process that uses germicidal UV light rays to sanitize water, air and surfaces that may be contaminated. Ultraviolet pool sanitizers emit a high intensity germicidal light ray that alters or disrupts the DNA or RNA of targeted organisms such as algae, bacteria, viruses, cysts and protozoa. The highly concentrated electromagnetic energy also destroys organic matter, eliminating the formation of dangerous chlorine by-products.
What does a UV sterilizer d
A UV sterilizer is used to control infections by stopping the spread of microorganisms from one fish/coral/invertebrate to another through the water. It is also used in pond applications to control free-floating algae. When operated correctly, free-floating microorganisms will be killed by the UV light. Note that the organisms must be in the water that flows to the UV sterilizer. The UV light has no residual effect and will not kill organisms attached to fish (e.g., adult stage of ich) or rocks (e.g., algae). 
 
How do UV sterilizers work?
The UV sterilizer utilizes a germicidal fluorescent lamp that produces light at a wavelength of approximately 254 nanometers (2537 Angstroms). The water with the bacteria/algae passes over the bulb (or around the bulb if a quartz sleeve is used) and is irradiated with this wavelength. As the light penetrates the bacteria/algae, it mutates the DNA (genetic material), preventing growth/multiplication of the organism.
 
Application
1.Food processing industry, including juices, milk, drinks, beer, practical oil  and canned food.
2.Electronic industry.
3.Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4.Households building, residential, office buildings, hotels, restaurants, water factories.
5.Purification and disinfection of shellfish, fish cleaning and disinfection
6.Military camp, field water supply system
7.Urban wastewater disinfection.
8.Swimming pool, other recreational water disinfection 
9.Thermal power, nuclear power plant  industrial, central air conditioning system cooling water.
10.Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11.Sea water, fresh water breeding, aquaculture  water
12.Agricultural water disinfection


 
Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.
 
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
 
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
 
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
 
                 DOSAGE is the product of intensity & time
dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
                              (μW-s/cm2)
               Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2)
 
model capacity Power inlet-outlet reactor panel Anchor G weight
m³/hour watt mm L×W×H cm screw Kg
YLCn-005 0.3 16 1/2″ 30×6×11 without without 5
YLCn-008 1 25 1/2″ 47×6.3×11 without without 10
YLCn-050 2 40 1″ 100×9×20 Φ8.9×25
(d×L)
69×4×Φ1 25
YLCn-150 6 80 1+1/4″ 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2″ 100×15.9×30 Φ8.9×45
(d×L)
69×7×Φ1 35
YLCn-300 12 160 2″ 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1″ 100×8.9×30 25×30×12
(W×H×D)
60×4×Φ1 45
YLC-150 6 80 DN32/11/4″ 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/11/2″ 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2″ 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/21/2″ 100×15.9×40 60×7×Φ1 120
YLC-500 20 240 DN65/21/2″ 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3″ 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4″ 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4″ 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5″ 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6″ 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6″ 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6″ 170×27.3×57 60×128×30
(W×H×D)
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6″ 170×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8″ 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8″ 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10″ 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10″ 176×52.9×95 60×150×40
(W×H×D)
120×22×Φ2.2 475
YLC-15K 600 3080 DN300/12″ 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14″ Designated Designated Designated Designated
YLC-25K 1000 4760 DN350/14″ Designated Designated Designated Designated
 Facts you should know 

Chloramines (residual chlorine)  is the smell you get from chlorine
Chloramines is the cause of eye and skin irritation  
Chloramines is the cause of composite building structure corrosion.
No microbe can immunize it's self against UV rays even those pathogens that cannot be killed by chlorination.
The adverse impact of pool chemicals, especially to children, is 5 times greater than passive smoking Product and installation costs of Ultraviolet water sterilisation reactors will depending on pool size and site location.
 

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now