• High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
  • High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
  • High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
  • High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
  • High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
  • High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

Certification: BV, ISO9001, SGS, CE
Application: Industry
Voltage: 220V
Disinfection Method: Ultraviolet
Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLC-5000
Medium Material
PP (Propene Polymer)
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

High Flow Commercial UV Bacteria Treatment  Water Purification Systems
 

UV Disinfection

Commercial bacteria & virus water treatment specifically designed to meet the demanding microorganism control requirements in high purity water systems. Typical Industrial disinfection applications include: Dairy, pharmaceutical, electronics, cosmetics, breweries, chemical plants, bottling plants, marine industries, petroleum industries, hospitals, drinking water, textile industry, swimming pools, microelectronics, universities, blood banks, medical centers, cosmetics and food industries, and research industries. Available flow rates from 10 gallons per minute to to 1,000,000 gallons per day

High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

 
How Ultraviolet Disinfection System Works
As water flows past the UV lamp(s) in a UV disinfection system, microorganisms are exposed to Ultraviolet light energy. Ultraviolet light alters the DNA material in cells so that bacteria, viruses, molds, algae and other microorganisms can no longer reproduce. The microorganisms are considered dead, and the risk of disease from them is eliminated. These Ultraviolet Disinfection Systems are designed for commercial & industrial applications. The process of UV Disinfection is accomplished without adding any harmful chemicals to your drinking water and does not distort the water or effect its pH value. UV Disinfection has an effective kill rate of 99.99% of most living microorganisms such as bacteria & viruses.
High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

UV Disinfection is suitable for Industrial & Commercial
  • Agriculture, Dairy, Livestock, Irrigation Water
  • Food & Beverage Industry
  • Beer Breweries, Wineries
  • Drinking Water
  • Ice Companies
  • Well Water
  • Aquaculture
  • Restaurants, Schools, Hospitals, Hotels
High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems
Technical parameters:
 
model Processing capacity (Ton/Hour) power (W)  inlet and outlet
(inch)
working pressure (Kg/cm 2 ) malfunction alert for UV lamp reactor dimension (cm) L×W×H dimension of panel(cm) anchor bolt  (cm) overall weight (Kg)
YLCn-005 0.3 16 1/2" 6 matched 30×6×11     5
YLCn-008 1 25 1/2" 6 matched 47×6.3×11     10
YLCn-050 2 40 1" 6 matched 100×9×20 Φ8.9×25
(diameter×length)
69×4×Φ1 25
YLCn-150 6 80 1+1/4" 6 matched 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2" 6 matched 100×15.9×30 Φ8.9×45
(diameter×length)
69×7×Φ1 35
YLCn-300 12 160 2" 6 matched 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1" 6 matched 100×8.9×30 25×30×12
(L×H×w)
60×4×Φ1 45
YLC-150 6 80 DN32/1 1/4 " 6 matched 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/1 1/2 " 6 matched 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2" 6 matched 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/2 1/2" 6 matched 100×15.9×40 50×78×25
(L×H×W)
60×7×Φ1 120
YLC-500 20 240 DN65/2 1/2" 6 matched 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3" 6 matched 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5" 6 matched 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6" 6 matched 170×27.3×57 60×128×30
(W×H×T)
 
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6" 6 matched 173×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8" 6 matched 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8" 6 matched 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10" 6 matched 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10" 6 matched 176×52.9×95 60×150×40
(W×H×T)
120×28×Φ2.2 475
YLC-15K 600 3080 DN300/12" 6 matched 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14" 6 matched confirmed  confirmed confirmed confirmed
YLC-25K 1000 4760 DN350/14" 6 matched confirmed confirmed confirmed

High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification SystemsHigh Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

Maintenance requirements for UV units

Lamp Replacement
UV lamps do not burn out as normal florescent lamps do. Instead, the UV lamps will solarize, reducing their intensity to about 60% of a new lamp after about one year of continuous use. When lamps are new, they will generate a dosage level near 60,000 µW-s/cm2 . When the dosage drops to 30,000 µW-s/cm2 (the minimum dosage needed to effectively kill bacteria) lamps should be replaced. Lamp life will be shortened significantly if the lamp is turned on and off more frequently than once every eight hours.

Monitoring Performance
Water should be sampled and tested for bacteria counts regularly. Sample before and after the UV unit to test its performance. Water should also be sampled in the animal rooms since bacteria regrowth can occur downstream of the UV unit.

Cleaning
As water passes through the UV unit, minerals, debris and other material in the water will deposit out and onto the quartz or Teflon sleeve. This will limit the penetration of UV rays through the sleeve and into the water. To maintain high clarity, the glass around the lamp must be cleaned regularly. Cleaning frequency depends on the water quality and will be minimal with RO, distilled, or deionized water.

Monitoring UV Dosage
UV light intensity meters are available which indicate the penetration of UV light through the glass sleeve and the water. Low intensity means the UV dose is too low to provide adequate disinfection. This meter will indicate when cleaning or lamp replacement is needed
High Flow Commercial UV Sterilizer Bacteria Treatment Water Purification Systems

FAQ:

Q. Does the water have to sit in the UV sterilizer to be disinfected? 
A. No. If the system is sized correctly, the water is disinfected as it flows through. 
 
Q. What if the water flows faster than is allowed through the system? 
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded. 
 
Q. How long does the lamp last? 
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water. 
 
Q. Are these systems bigger energy users? 
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
 
Q. My water is sometimes cloudy. Is that a problem? 
A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now