• 40000m3/H Open Channel UV Lamp System in Water Treatment Plant
  • 40000m3/H Open Channel UV Lamp System in Water Treatment Plant
  • 40000m3/H Open Channel UV Lamp System in Water Treatment Plant
  • 40000m3/H Open Channel UV Lamp System in Water Treatment Plant
  • 40000m3/H Open Channel UV Lamp System in Water Treatment Plant
  • 40000m3/H Open Channel UV Lamp System in Water Treatment Plant

40000m3/H Open Channel UV Lamp System in Water Treatment Plant

Certification: ISO9001, CE
Application: Water Treatment
Voltage: 220V
Disinfection Method: Ultraviolet
Item: Opopen Channel UV Lamp System
Bactericidal Efficienc: 98% Kill Total Coliforms
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YL-320W-5-24
Material
Stainless Steel Ss304, Ss316
Power
38kw
Lamps
120PCS*320W
Lifespan of UV Lamp
9000-12000 Hours
Power Supply
110V~480V Can Be Changed
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water
Watsewater, Municipal, Aquaculture Recirculating
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
842121999
Production Capacity
5000 Sets/Year

Product Description

40000m3/h Open Channel UV Lamp System In Water Treatment Plant
 

Technical parameters

Capacity:≥2,000 T/D
Configuration:multiple modules in parallel
UV lamps:Europe/US imported,320W/lamp
System type:open-channel
Voltage:220V/380V
Operating pressure:≤0.8Mpa
Disinfection rate:over 99.99%

Key components:
1. UV module;
2. Manual/automatic cleaning system;
3. Power cabinet;
4. Electronic ballast;
5. US imported UV lamps from LIGHTSOURCE with a power of 320W and lifetime up to 12,000 hours;
6. Air cooling system;
7. Electric wiring and accessories;
8. Support rack;
9. System capacity is up to 8,000 T/D or more
10. Automatic water level control, UV intensity monitor, central PLC controller from Siemens with color touch screen.
40000m3/H Open Channel UV Lamp System in Water Treatment Plant
40000m3/H Open Channel UV Lamp System in Water Treatment Plant
 

40000m3/H Open Channel UV Lamp System in Water Treatment Plant
40000m3/H Open Channel UV Lamp System in Water Treatment Plant
 
Typical Applications Wide range of clean / waste water treatment
Lamp Type Low-pressure, high-efficiency amalgam (monochromatic)
Ballast Type Electronic, high-efficiency, variable output (60~100% power)
Input Power Per Lamp 320, 550 Watts/pc
Lamp Configuration Horizontal, parallel to flow; Vertical to flow; 65°with the folow
Lamp Brand & Origin Lightsource/Philip/Heraeus/Domestic brand
Module Configuration 8, 10 or 12 lamps per module
Level Control Device Options Automatic Level Controller, Fixed weir or motorized weir gate
Water Level Sensor 1 electrode low water level sensor per channel
UV Intensity Sensor 1 UV detector for one sterilizer module
Working Temperature 4~60ºC/39.2~140ºF
Working Pressure 6 bar / 100psi
Enclosure Ratings
Module Frame/Ballast Enclosure TYPE 6P (IP68) / TYPE 6P (IP67)
All Other Enclosures TYPE 4X (IP56)
Ballast Cooling Method Convection / Air conditioning / Forced air required
Installation Location Indoor or outdoor
Module Frame/Chamber SS304/SS316, Internal finish - Ra(max)0.8um
Sleeve Cleaning System
Auto-Cleaning System Automatic Chemical/Mechanical (optional)
Auto-Cleaning WW Gel Non-corrosive, operator-friendly, food-grade
Sleeve Spec Quartz sleeves, UV transmittance >92%
Controller PLC-based (Siemens/ Schneider PLC Standard Platform)
Electrical Requirements
Power Supply 220V, 50Hz (can be customized )
Electrical Cabinet Working temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)

To customers details
Deatils:
01. What is the source of raw water to be treated?
 --is it underground water or well water?or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
 --most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?


Open channel UV water sterilizer systems are mainly used at the municipal water/wastewater treatment plants for water recycling and effluent disinfection to ensure a better level of environmental protection.
UV disinfection is an effective and environmentally friendly alternative to the conventional chlorine effluent disinfection. Nowadays more than 15% of 2000 waste water treatment plants in North America have chosen the UV as the primary disinfection method. UV disinfection has proved its safety, reliability, efficiency, and economical characteristics over the years.
 Open channel UV sterilziers GT series have been used for waste water, sewage water desinfection in order to achieve a lower envirionment pollution drainage.

Our Service:

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
Mobile phone: +86 13585066069
Alibaba website: http://yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year
After-sale service:800-827-87-226






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now