Side Stream Water Treatment Equipment for Cooling Water System

Usage: Chemical Industry
Motive Force: Electric power
Certification: CE
Input Supplying: 220V, 50Hz
Sterilization Efficiency: More Than99%
Working Voltage: Less Than36V
Customization:

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YL-II-10G
Raw Water Temperature
0 to 95 Centigrade
Corrosive Rate
More Than97%
Qualified Water Quality
Reach The National Standard
The Loss of Water Head
0.2 to 1.0m
Total Hardness
Less Than700mg/L
Removal and Prevent in Scale
More Than99%
Transport Package
Plywood Case Into Container
Specification
CE, GSG
Trademark
YLD
Origin
Jiangyin, Jiangsu, China
HS Code
8421219990
Production Capacity
5000 Sets/Year

Product Description

Product Introduction
By-pass flow water processor is a new product developed on the basis of full-flow water processor, with the principle of overlapped low-voltage pulsed electric field, which can automatically adjust output signals depending on water quality. After treatment with water processor, the density water of molecule is decreased and its structure is also changed, for example, longer dipole moment of water molecule, higher polarity and larger surface tension, so that water molecule can be used for scale dissolution and further for scale removal.
Electrodes may act on the processor and the processor will generate a large number of small crystals with the function of scale prevention. These crystals can remove ions easy to form scale by chemical reaction, form loose aragonite crystals after reaction, and finally automatically be discharged through drain valve. Dissolved oxygen of water being treated by the processor will be activated. Electrolyzed by electrodes, water will be decomposed into OW, 02, H202 and a large number of reactive oxygen species which are featured with strong oxidizing properties and can thoroughly kill microorganisms and various algae. As a result, bacteria and algae can be removed and scale can be prevented.
Meanwhile, the pipe wall of system will be further oxidized by a mass of active oxygen generated by the processor and a dense oxidation film will be formed, such as ferroferric oxide. The oxidation film can make the pipe wall passivated, prevent pipeline corruption, increase the service life of system and further prevent equipment corruption.

Product Features
Only consume 1%— 3% of the water system flow should be treated by by— Pass flow water processor with easy installation.
Legionella will be killed by strong pulsed electric field.
No need of any chemicals, without generation of second pollution, environmental protection
Rust and yellow water removal
Turbidity reduction
Obvious effects


Features
Kill bacteria in the water
Inhibit algae
Anti equipment pipeline corrosion
Kill the Legionella
Waterproof scale, descale
Remove suspended solids
Applicable Scope
Central air conditioning cooling, chilled water system
Refrigeration cycle water system
Industrial cooling water circulation system
Heat exchange systems and cooling tower system

System properties
Open cooling water circulating system
Closed circulating water system
1
By-pass flow water processor (side stream treatment equipment)
As there are differences between open cooling water system and closed circulating water system (as shown in the table below), it is necessary to adopt different water processors for water treatment based on their own features.
System water is open, so that heat will be released to the air by means of water evaporation.
System water is closed, used for heat delivery.
Not concentrated
Weak
Slow
No
Water is concentrated or not Concentrated
Trend of water scale Strong
Growth of bacteria Fast
Growth of algae Yes
Based on the drift diameter of header pipe, F-type water processor is suitable for open cooling water system, that is, applicable drift diameter of the water processor is the same as that of the header pipe of the system.
Based on the drift diameter of header pipe, G-type water processor is suitable for closed cooling water system, that is, applicable drift diameter of the water processor is the same as that of the header pipe of the system
TypeDimensionDetailed dimensionConnecting pipeThe loss of water head
(mm)
Power less than
(w)
Weight
(Kg)
ModelPipe dimension (mm)L
(mm)
W
(mm)
H
(mm)
A
(mm)
B
(mm)
C
(mm)
Inlet and outlet diameter
(mm)
Outfalldrift diameter(mm)
YLD-II-1G809005601200500350120 25*250.250100
YLD-II-2G1009005601200500350120 25*250.490100
YLD-II-3G1509005601200500350120 25*250.7120102
YLD-II-4G2009005601200500350120 25*251.0160110
YLD-II-5G2509005601200500350120 25*251.0220110
YLD-II-6G3009005601200500350120 32*251.0300115
YLD-II-7G3509005601200500350120 32*251.0500120
YLD-II-8G4009005601200500350120 40*251.0600130
YLD-II-9G4509505801200500350120 40*251.0800160
YLD-II-10G500950580120050035012050251.0900180
YLD-II-11G600950580120050035012050251.01100190
YLD-II-12G70010001100120050035012065251.01400236
YLD-II-13G80010001100120050035012065251.01700250