8040 Membrane Reverse Osmosis for RO Water Purification

Product Details
Customization: Available
Certification: ISO9001
Salt Rejection Rate: 99.0%
Still deciding? Get samples of US$ 30000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • 8040 Membrane Reverse Osmosis for RO Water Purification
  • 8040 Membrane Reverse Osmosis for RO Water Purification
  • 8040 Membrane Reverse Osmosis for RO Water Purification
  • 8040 Membrane Reverse Osmosis for RO Water Purification
  • 8040 Membrane Reverse Osmosis for RO Water Purification
  • 8040 Membrane Reverse Osmosis for RO Water Purification
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • To customers
  • Certifications
  • After Sales Service
Overview

Basic Info.

Model NO.
YLD-RO-20T
Application
Industry
Capacity
50 Gallon
Input Flow
15m3/Hr
Output Flow
10m3/Hr
Style
Vertical
Motive Force
Electric Power
Type
Reverse Osmosis
Usage
Beverage Plants
Recovery
70%
Power Supply
220-380V
Material
SS304 & UPVC
Working Temperature
20~35ºC
Transport Package
Plywood Case Into Container
Specification
10m3/hr
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Production Capacity
5000 Sets/Year

Packaging & Delivery

Package Size
300.00cm * 200.00cm * 220.00cm
Package Gross Weight
3000.000kg
Lead Time
30 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

8040 Membrane Reverse Osmosis For RO Water Purification
 
8040 Membrane Reverse Osmosis for RO Water Purification
8040 Membrane Reverse Osmosis for RO Water Purification

 
Product Description

Complete reverse osmosis process including the pretreatment and post-treatment that is generally required for highly contaminated water:

A) Raw Water Storage Tank

Although some RO Systems can draw water right out of a well or pipe feed, most reverse osmosis systems start with a large tank that stores the contaminated water. Not having enough feed water can damage a pump, so having a large storage tank for your intake water is an easy way to make sure your pump lasts for as long as possible.
 

8040 Membrane Reverse Osmosis for RO Water Purification

B) Feed Water Pump

pump provides the initial pressure for the Treatment System. This motor usually provides enough water pressure to get through any pretreatment as well as the RO membranes, but if it doesn't a booster pump may be necessary farther down the line.

 

C) Multi-media Filter

As much as we hate to admit it, there are some things that membranes can't purify. Nitrates, a common contaminant found in fertilizers and animal waste, are a good example of particles that dissolve too well in water for reverse osmosis to catch them. Things like foul odor and taste usually aren't prevented by reverse osmosis, either. A Multi-Layer filter can be filled with media that specifically targets the things your RO system can't catch. If you need to eliminate these contaminants, a multi-layer filter is a must. An example of MMF or multi media filters. See our media filter series
8040 Membrane Reverse Osmosis for RO Water Purification

D) Activated Carbon Filter

Activated carbon filters are a good solution to reduce organic, bad taste, smell and chlorine from the water.See our carbon filter series.

E) Automatic Water Softener

Automatic water softeners are designed to remove water hardness, calcium and magnesium ions, for small RO systems, we usually recommend water softeners instead of the antiscalant chemical dosing. See our water softener series.
8040 Membrane Reverse Osmosis for RO Water Purification

F) Antiscalant Chemical Dosing System

For larger RO systems, we use antiscalant dosing systems to dose our PA0100 antiscalant RO chemical, which helps in preventing membrane fouling. For more information, please visit our CDS-Series chemical dosing pumps.See our chemical dosing device series.
8040 Membrane Reverse Osmosis for RO Water Purification

G) Reverse Osmosis System

We finally have our reverse osmosis system. If a booster pump is necessary, it will typically be just before this step. The reverse osmosis system can produce up to one million gallons of product water a day from a steady intake, as well as a sizable amount of waste. Usually the wastewater can be dumped down the drain, but check with your local water authorities in case it needs to be handled with care.

H) Product Water Storage Tank

The permeate from the reverse osmosis system will usually go to a large tank, where it is held for use. If it didn't, the system would need to be running in order to have access to fresh water, which can be inconvenient. Sometimes, a RO system pumps water directly into a well or aquifer for recharging instead of being used in many of the normal industries or applications it is used in.

I) Chlorination Dosing System

If the permeate water is intended to be stored for more than one day, it is highly recommended to dose some chlorine to maintain clean and non contaminated water.
8040 Membrane Reverse Osmosis for RO Water Purification

J) Water Pump (Re-pressurization)

This pump repressurizes the permeate water to the point of use ends. This is selected based on the overall travelling distance and required head. This pump must be selected in stainless steel to prevent any contamination to the permeate water.

K) Water UV Sterilizer

The UV sterilizer is placed after the storage tank, and as a final disinfection device. Most of the time, we either use post chlorination as a disinfectant agent, or ultraviolet sterilization.See our UV sterilizer series.

                            
 8040 Membrane Reverse Osmosis for RO Water Purification
                  
Product Parameters
 
Type of ions
 
Removing efficiency
 
Type of ions
 
Removing efficiency
 
AI 3+ 95-99% SO 2- 4 90-99%
Mn 2+ 95-99% HPO 2- 4 90-99%
Ca 2+ 92-99% CO 2- 3 80-95%
Mg 2+ 92-99% SiO 2- 3 75-90%
K + 75-93% CF - 85-95%
Na + 75-95% HCO - 3 80-95%
NH4 + 70-90% CI - 80-95%
PO 3- 4 90-99% NO - 3 50-75%
               
To customers
  1. Flow rate (GPD, m3/day, etc.)
  2. Feed water TDS and water analysis: this information is important to prevent membranes from fouling, as well as help us choose the correct pre-treatment.
  3. Iron and manganese must be removed before the water enters reverse osmosis unit
  4. TSS must be removed before entering the Industrial RO system
  5. SDI for feedwater must be less than 3
  6. Water should be free from oil and grease
  7. Chlorine must be removed
  8. Available voltage, phase, and frequency (208, 460, 380, 415V)
  9. Dimensions of projected area where Industrial RO System will be installed

 

Certifications
8040 Membrane Reverse Osmosis for RO Water Purification
8040 Membrane Reverse Osmosis for RO Water Purification
8040 Membrane Reverse Osmosis for RO Water Purification
After Sales Service

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
website: http:yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year

8040 Membrane Reverse Osmosis for RO Water Purification

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now