• Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
  • Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
  • Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
  • Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
  • Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
  • Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment

Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment

Certification: ISO9001, CE
Application: Industry
Voltage: 220V
Disinfection Method: Ultraviolet
Bactericidal Efficienc: 98% Kill Total Coliforms
Material: Stainless Steel Ss304, Ss316
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Jiangsu, China
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)

Basic Info.

Model NO.
YLC-1000G
Medium Material
PP (Propene Polymer)
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Trademark
YLD
Origin
Jiangyin, Jiangsu
HS Code
842121999
Production Capacity
5000 Sets/Year

Product Description

Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
The open sewer disinfection technical system adopts the advanced IN-C disinfection technology through the special process design. high-efficiency, high-intensity and long service life UV-C lamp tubes, superior for the ballasts of reliable performance and electric-control system. It adopts the UV-C wave (T254nm) in high-efficiency and broad-spectrum killing of the bacteria and viruses so as to achieve the goal of water purification and disinfection.
As the first-class high-efficiency UV-C lamp tubes and superior-performance electric control system, the UV disinfection system enjoys power consumption far lower than that of the traditional UV disinfection system. In terms of the system design, designers of our Company have paid full attention to the attenuation of light intensity of UV lamp tubes within the service life and decrease of sterilization rate due to reduction of light intensity caused by sedimentation on the surface of the quartz tubes. Therefore, a large margin has been set when designing the disinfection system. Even when the light intensity of the lamp tubes drops to 60% of the rated value, the whole system can maintain normal operation. It has so far been broadly accepted in more and more fields for its unique and advantageous performances (particularly in disinfection of large water bodies and recycled reclaimed water).
 Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment
Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment

Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment

Water quality factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution

Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment

Disinfection system factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Hydrodynamic design of the sterilizer (Maximize the use of UV performance to increase the disinfector efficiency and reduce the water pressure loss
2. Lamp tube performance (including the system aging)
3. Arrangement of lamp tubes
4. Scale coefficient of lamp tubes
5. Performance of ballast
 Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment


Advantages:
- Small to large capacity range, easy to expand capacity by modular design.
- Automatic wiper mechanism eliminating the requirement of manual cleaning of quartz sleeves.
- High efficiency, long lamp life amalgam technology.
- Overall control features such as UV monitoring, remote controlling, system monitoring and water 
  level regulator.
- Standardized open channel type model equipped with microprocessor control.
- Applicable for medium to large size plants.
- Module with one-touch connector

Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment




Design of the concise and lightweight bent frame
1. IP68 or equal grade of sealing protection. High-efficient secure multi-level sealing waterproof design.
2. The module adopts the push-in connectors with the less water resistance so as to guarantee the water incoming before disinfection and water discharge after disinfection.
3. There is little change in water level as to guarantee a stable sterilization effect.
4. It does not need any special tools to disassemble and assemble the disinfection module.
 


The cleaning ring of the quartz socket tube
Long-term contacting between the quartz socket tubes with the wastewater will surely generate scales, which must be cleaned effectively. The cleaning ring of this product is simple in structure and resistant to aging. The flexible cleaning parts of the cleaning ring can positively adapt to the quartz tubes. Even when the tubes are installed in deviations, the cleaning ring can ensure very good cleaning effect, namely, without abrading or damaging the quartz tubes.
 
Open Channel Type UV Sterilizer for Waste Water and Sewage Water Treatment


Automatic cleaning device
1. Mechanical self-cleaning device driven by compressed air;
2. The cleaning device and the uv light intensity detector are in linked operation;
3. Having (the optional) manual or automatic working statuses;
4. The low-abrasion and locking-free advantages have laid solid foundation for the UV system to realize the high-efficiency sterilization.
 



Advanced control system
1. The automatic control center has the remote-control and site-control functions, equipped with the world-class parts and components of superior quality and reliable operating performance.
2. The site control is conducted by the man-machine interface, which consists of the operation recording, fault alarming and maintenance warning functions, easy and simple to operate.
3. The UV intensity output and signal PLC link-control can be monitored online so as to guarantee the UV dosage which can achieve the designed disinfection effect.
 



Applicable Range
It is applicable to disinfection of water for the large, medium and small sewage treatment plants, landscape water, aquaculture water, reclaimed water recycling and hospitals.






Comparion Of Disinfection Methods:

Factors to be considered

Liquid chlorine disinfection

Chlorine dioxide disinfection

Ozone disinfection

UV disinfection

Time to be processed

30 min

≤30min

5~10min

30~60s

Dosage (mg/l)

2~20

5~10

1~3

30~40

Efficiency of inaction bacteria

High

High

High

High

Efficiency of bacteria and viruses

Lower middle

Middle

High

High

Water quality factors

More easily affected by PH and temperature

More easily affected by PH and temperature

Less affected by PH and temperature

Less affected by PH and temperature

Operation complexity

Simple to middle

Middle

Complicated

Simple to middle

Economical efficiency

Operation cost

Lower middle

Middle

Above the average

Lower middle

Area

Large

Less

Small

Small

Maintenance work

Large

Less

Large

Small

Adverse impact

Safety during transportation

Yes

Yes

No

No

Site security

Very high

Middle

Middle

Smaller

Poisoning against the fishes and large invertebrates

Toxic

Poisonous

No

No

Whether there exists the toxic by product

Yes

Exist in small quantity

Yes

No

Disposal of the cleaning agents

No

No

No

Have

Whether or not to increase the content of the soluble solid

Yes

Yes

No

No

Corrosively

Yes

Yes

Yes

No

High energy consumption

No

No

Yes

Yes

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now